PatchSiren cyber security CVE debrief
CVE-2024-43890 Siemens CVE debrief
CVE-2024-43890 is a MEDIUM severity vulnerability (CVSS 5.5) in the Linux kernel tracing subsystem, specifically an overflow in get_free_elt() that can lead to infinite loops and CPU hangs when the tracing map becomes full. The vulnerability was published on 2025-08-12 and last modified on 2026-02-25. Siemens has identified this vulnerability as affecting certain industrial networking products running SINEC OS, including the RUGGEDCOM RST2428P and SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family devices. However, per the CISA advisory ICSA-25-226-07, the impact assessment for these products is marked as 'Misinformed,' indicating the vulnerability's applicability or impact may be limited or incorrectly characterized in the initial assessment. The vulnerability stems from improper input validation (CWE-20) in the kernel's tracing map implementation. Organizations should consult Siemens ProductCERT advisory SSA-355557 for definitive product-specific guidance and patch availability.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Organizations operating Siemens RUGGEDCOM RST2428P, SCALANCE XC/XR series, or other SINEC OS-based industrial networking equipment should monitor this advisory. Security teams in OT/ICS environments should prioritize vendor guidance from Siemens ProductCERT over initial CISA impact assessments given the 'Misinformed' classification.
Technical summary
An integer overflow in the Linux kernel's tracing subsystem function get_free_elt() can cause infinite loops and CPU hangs when the tracing map reaches capacity. The vulnerability is classified under CWE-20 (Improper Input Validation). Siemens industrial networking products running SINEC OS are identified as potentially affected, though the CISA advisory marks the impact as 'Misinformed,' suggesting the initial assessment may require correction or clarification. The vulnerability is not listed in CISA's Known Exploited Vulnerabilities catalog.
Defensive priority
medium
Recommended defensive actions
- Review Siemens ProductCERT advisory SSA-355557 for definitive product-specific impact assessment and patch guidance
- Verify SINEC OS version and tracing subsystem configuration on affected Siemens devices
- Apply vendor-provided firmware updates when available per Siemens security advisory
- Monitor CISA ICS advisories for updates to impact assessment
- Implement network segmentation for industrial control systems per CISA recommended practices
- Review and apply CISA Defense in Depth strategies for ICS environments
Evidence notes
Vulnerability description sourced from CISA CSAF advisory ICSA-25-226-07. Impact assessment marked as 'Misinformed' per advisory threats section. Siemens ProductCERT SSA-355557 identified as authoritative source for remediation guidance. CVE published date 2025-08-12 used per timeline fields; modified date 2026-02-25 reflects CISA republication updates.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-43890 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-43890
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-43890 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-43890
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-226-07.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-355557.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-355557.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.