PatchSiren cyber security CVE debrief
CVE-2024-42224 Siemens CVE debrief
A logic error in the Marvell 88E6xxx Distributed Switch Architecture (DSA) driver for Linux could lead to incorrect handling of empty lists. The vulnerability stems from an improper check when determining if a list is empty, potentially causing unexpected behavior in network switch operations. Siemens has identified this as affecting certain industrial networking products running SINEC OS, though the specific impact is characterized as 'Misinformed' in the advisory. The issue was originally published in the Linux kernel context and subsequently incorporated into Siemens' third-party component security assessment.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- Unknown
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Organizations operating Siemens industrial networking equipment including RUGGEDCOM RST2428P switches and SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family devices running SINEC OS. System administrators managing OT/ICS networks with Marvell-based switch hardware should monitor for vendor updates.
Technical summary
The vulnerability exists in the mv88e6xxx driver within the Linux kernel's Distributed Switch Architecture (DSA) subsystem. The driver performs an incorrect check when evaluating whether a list structure is empty, which can lead to improper state management during network switch operations. This affects Siemens industrial networking products utilizing SINEC OS that incorporate the vulnerable kernel component. The DSA subsystem is responsible for managing hardware switches through Linux network interfaces, making this relevant to embedded and industrial networking deployments.
Defensive priority
medium
Recommended defensive actions
- Review Siemens ProductCERT advisory SSA-355557 for affected product configurations and patch availability
- Verify SINEC OS version and installed kernel packages on affected Siemens industrial networking equipment
- Apply vendor-provided firmware updates when available per Siemens maintenance procedures
- Monitor network switch logs for anomalous behavior in DSA-managed ports
- Implement network segmentation for critical industrial control systems as defense-in-depth measure
Evidence notes
The vulnerability description 'net: dsa: mv88e6xxx: wrong check on empty list' indicates a logic flaw in the Marvell 88E6xxx DSA driver's list handling. The CISA advisory ICSA-25-226-07 (republished 2026-02-25) tracks this as part of Siemens' third-party component security assessment for SINEC OS-based products. The threat category 'Misinformed' suggests the primary concern relates to incorrect state or information rather than direct code execution. The advisory underwent multiple revisions, with the most recent update (2026-02-25) reflecting republication based on Siemens ProductCERT SSA-355557.
Official resources
-
CVE-2024-42224 CVE record
CVE.org
-
CVE-2024-42224 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
2025-08-12