PatchSiren

PatchSiren cyber security CVE debrief

CVE-2024-41978 Siemens CVE debrief

An authenticated remote attacker could potentially forge 2FA tokens of other users due to sensitive information about 2FA token generation being inserted into log files on affected Siemens devices. This vulnerability affects Siemens RUGGEDCOM and SCALANCE devices. The issue arises from the logging of sensitive information related to 2FA token generation, which could be exploited by an attacker to forge 2FA tokens. Defenders should assess exposure and apply mitigations to prevent potential 2FA token forgery.

Vendor
Siemens
Product
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
CVSS
MEDIUM 6.5
CISA KEV
Not listed in stored evidence
Original CVE published
2024-08-13
Original CVE updated
2024-08-13
Advisory published
2024-08-13
Advisory updated
2024-08-13

Who should care

Defenders responsible for Siemens RUGGEDCOM and SCALANCE devices, industrial control system security teams, and administrators of affected devices should assess exposure and apply mitigations.

Why it matters

CVE-2024-41978 allows authenticated remote attackers to potentially forge 2FA tokens on Siemens RUGGEDCOM and SCALANCE devices due to sensitive information being logged. Defenders should verify exposure, restrict log access, apply updates, and monitor for suspicious activity.

  • Potential 2FA token forgery by authenticated remote attackers
  • Increased risk of unauthorized access to affected devices
  • Need for log file monitoring and access restriction
  • Priority for applying vendor-provided security updates

Technical summary

Affected Siemens devices insert sensitive information about 2FA token generation into log files. An authenticated remote attacker could potentially forge 2FA tokens of other users. Siemens provides an update to V8.1 or later as a remediation. The vulnerability is related to the logging of sensitive information, which could lead to 2FA token forgery. Defenders should prioritize verifying exposure of affected devices, checking for log file access and modification, and applying vendor-provided updates to prevent potential exploitation.

Defensive priority

Defenders should prioritize verifying exposure of Siemens RUGGEDCOM and SCALANCE devices, checking for log file access and modification, and applying vendor-provided updates.

Recommended defensive actions

  • Verify exposure of Siemens RUGGEDCOM and SCALANCE devices in the environment
  • Check for and restrict access to log files on affected devices
  • Apply vendor-provided updates to V8.1 or later for affected devices
  • Monitor for suspicious 2FA token activity and implement additional authentication measures
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and CISA CSAF advisory provide details on the vulnerability, affected products, and vendor recommendations. However, specific details on exploitation or victim impact are not provided. The lack of information on actual exploitation or specific victim impact limits the understanding of the vulnerability's real-world effects. Defenders should verify the exposure of affected Siemens devices, check for log file access and modification, and apply vendor-provided updates. The CVE record and CISA CSAF advisory serve as primary

Sources and references

Verified primary and authoritative sources

  • CVE-2024-41978 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-41978

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-41978 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-41978

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • CVE-2024-41978

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-01.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-087301.json

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-087301.html

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Supplemental source

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.