A path traversal vulnerability in the importCertificate function of the SINEC NMS Control web application allows authenticated attackers to delete arbitrary certificate files on the installation drive. The vulnerability was published on August 13, 2024, with a CVSS 3.1 score of 5.5 (Medium severity). Authentication is required for exploitation, limiting the attack surface to users with valid credentials. The vulnerability specifically affects certificate file operations through improper path validation during certificate import operations.
- Vendor
- Siemens
- Product
- SINEC NMS
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-08-13
- Original CVE updated
- 2024-08-13
- Advisory published
- 2024-08-13
- Advisory updated
- 2024-08-13
Who should care
Organizations operating Siemens SINEC NMS for industrial network management, particularly those relying on certificate-based authentication and encryption for operational technology environments. Security teams responsible for industrial control system infrastructure and certificate lifecycle management should prioritize this update to prevent potential service disruption from certificate deletion.
Technical summary
The importCertificate function in SINEC NMS Control fails to properly validate file paths, enabling authenticated users to traverse directory structures and delete arbitrary certificate files on the host system. The vulnerability requires high privileges (PR:H) but is exploitable over the network with low attack complexity (AC:L). Scope change (S:C) indicates impact beyond the vulnerable component. The CVSS environmental score modifiers show proof-of-concept exploit availability (E:P), official fix available (RL:O), and confirmed report credibility (RC:C). Remediation is available through vendor update to version 3.0 or later.
Defensive priority
medium
Recommended defensive actions
- Apply vendor fix by updating SINEC NMS to version 3.0 or later
- Restrict network access to SINEC NMS Control web application to authorized administrative hosts only
- Monitor for unauthorized certificate file deletion operations on SINEC NMS installation directories
- Implement defense-in-depth strategies for industrial control systems per CISA guidance
- Review and validate certificate management procedures to ensure proper access controls
Evidence notes
Vulnerability description and remediation guidance sourced from CISA ICS advisory ICSA-24-228-06 and Siemens security advisory SSA-784301. CVSS vector indicates network attack vector with low attack complexity, high privileges required, no user interaction, and scope change with low impact to integrity and availability.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-41938 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-41938
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-41938 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-41938
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-06.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-784301.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-784301.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-06
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance