PatchSiren

PatchSiren cyber security CVE debrief

CVE-2024-41907 Siemens CVE debrief

CVE-2024-41907 is a medium-severity vulnerability affecting Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0), published on 2024-08-13. The web server component lacks general HTTP security headers, increasing susceptibility to clickjacking attacks where an attacker could trick users into interacting with hidden interface elements. The CVSS 3.1 score of 4.2 (AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N) reflects network attack vector with high complexity, requiring user interaction but no privileges. Siemens has released version 2.0 or later to address this issue. As an industrial control system component, this vulnerability carries operational technology risk where successful clickjacking could lead to unauthorized configuration changes or information disclosure.

Vendor
Siemens
Product
SINEC Traffic Analyzer (6GK8822-1BG01-0BA0)
CVSS
MEDIUM 4.2
CISA KEV
Not listed in stored evidence
Original CVE published
2024-08-13
Original CVE updated
2024-08-13
Advisory published
2024-08-13
Advisory updated
2024-08-13

Who should care

Organizations operating Siemens SINEC Traffic Analyzer in industrial network environments, OT security teams responsible for network monitoring infrastructure, and administrators managing web-accessible industrial control system components.

Technical summary

The SINEC Traffic Analyzer web server does not implement standard HTTP security headers including X-Frame-Options and Content-Security-Policy frame-ancestors directives. This configuration gap allows the application to be embedded in malicious frames, enabling clickjacking attacks where user actions are redirected to attacker-controlled functionality. The vulnerability requires user interaction and network access but no authentication, with potential impacts including low confidentiality and integrity compromise.

Defensive priority

medium

Recommended defensive actions

  • Update SINEC Traffic Analyzer to version 2.0 or later per vendor guidance
  • Implement Content-Security-Policy frame-ancestors directive and X-Frame-Options header as defense-in-depth measures
  • Review web application security configurations for missing security headers
  • Apply network segmentation to limit exposure of industrial control system web interfaces
  • Monitor for unauthorized configuration changes that could indicate successful clickjacking exploitation

Evidence notes

Vulnerability description and remediation guidance sourced from CISA ICS advisory ICSA-24-228-04 and Siemens security advisory SSA-716317. CVSS vector and affected product identification confirmed through CSAF product tree data.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-41907 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-41907

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-41907 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-41907

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-04.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-716317.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-716317.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-04

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.