CVE-2024-41788 Siemens CVE debrief
CVE-2024-41788 is a critical Siemens issue affecting the SENTRON 7KT PAC1260 Data Manager web interface. According to the advisory, specific GET request parameters are not sanitized, which can allow an authenticated remote attacker to execute arbitrary code with root privileges. The source corpus also states that no fix is currently planned, so compensating controls are important.
- Vendor
- Siemens
- Product
- SENTRON 7KT PAC1260 Data Manager
- CVSS
- CRITICAL 9.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-04-08
- Original CVE updated
- 2025-04-08
- Advisory published
- 2025-04-08
- Advisory updated
- 2025-04-08
Who should care
OT/ICS operators, Siemens SENTRON 7KT PAC1260 Data Manager administrators, plant and facility engineers, and security teams responsible for industrial web interfaces and remote access controls.
Technical summary
The advisory describes an input-sanitization failure in the device web interface. In specific GET requests, parameters are not properly sanitized, creating a path for authenticated remote code execution with root privileges. The provided CVSS vector is CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H, reflecting network reachability, low attack complexity, required high privileges, and high impact. The supplied corpus does not provide affected version ranges, so this debrief avoids version-specific assumptions.
Defensive priority
Immediate. This is a critical authenticated RCE issue on an industrial product, with root-level impact and no fix currently planned in the source advisory.
Recommended defensive actions
- Restrict access to the device web interface to trusted management networks only.
- Enforce least-privilege access and review who can authenticate to affected devices.
- Segment affected OT assets from broader IT and user networks.
- Monitor for suspicious authenticated web activity, unexpected configuration changes, and abnormal device behavior.
- Apply vendor- and CISA-recommended compensating controls while awaiting any future remediation updates.
- If risk cannot be sufficiently reduced, consider operational isolation or replacement planning for exposed assets.
Evidence notes
Core facts come from the CISA CSAF advisory and the linked Siemens advisory references. The source states that the web interface does not sanitize input parameters in specific GET requests, that an authenticated remote attacker could execute arbitrary code with root privileges, and that no fix is currently planned. Publication and modification dates in the supplied timeline are 2025-04-08, which are used here as advisory dates rather than issue dates.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-41788 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-41788
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-41788 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-41788
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-100-06.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-187636.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-187636.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-100-06
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.