A medium-severity vulnerability in Siemens Location Intelligence family products allows unauthenticated on-path attackers to read and modify data due to weak default cipher configurations. Published August 13, 2024, this issue affects the web server component of affected products. The attack requires adjacent network access, high attack complexity, and user interaction, but successful exploitation enables confidentiality loss and high-impact integrity/availability compromise. Siemens has released version 4.4 as a remediation. No known exploitation in ransomware campaigns has been reported.

Vendor
Siemens
Product
Location Intelligence family
CVSS
MEDIUM 6.7
CISA KEV
Not listed in stored evidence
Original CVE published
2024-08-13
Original CVE updated
2024-08-13
Advisory published
2024-08-13
Advisory updated
2024-08-13

Who should care

Organizations operating Siemens Location Intelligence family products in industrial environments, particularly those with web-facing or network-accessible deployments. Security teams responsible for TLS/SSL configuration management and industrial control system defense should prioritize this update.

Technical summary

The web server in Siemens Location Intelligence family products ships with weak cipher suites enabled by default. An unauthenticated attacker positioned on the network path between legitimate clients and the affected device can exploit this configuration to perform a man-in-the-middle attack, decrypting and modifying traffic. The CVSS 3.1 score of 6.7 reflects adjacent network access requirements, high attack complexity, and necessary user interaction, with potential for high impact on integrity and availability. Proof-of-concept exploitation has been reported. Siemens provides version 4.4 as the vendor fix.

Defensive priority

medium

Recommended defensive actions

  • Update Siemens Location Intelligence family products to version 4.4 or later to address weak cipher configurations
  • Review TLS/SSL cipher suite configurations on affected systems to ensure only strong ciphers are enabled
  • Implement network segmentation to limit exposure of affected devices to untrusted networks
  • Monitor for anomalous network traffic patterns that may indicate on-path attack attempts
  • Apply defense-in-depth strategies per CISA ICS recommended practices for industrial control systems

Evidence notes

CISA CSAF advisory ICSA-24-228-07 confirms Siemens as vendor and Location Intelligence family as affected product. CVSS 3.1 vector AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:O/RC:C sourced from CSAF metadata. Remediation guidance specifies update to V4.4 or later.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-41681 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-41681

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-41681 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-41681

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-07.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-720392.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-720392.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-07

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

Methodology and review provenance