A vulnerability in the Transparent Inter-Process Communication (TIPC) protocol implementation could allow a crash to occur before decryption is performed. This affects Siemens industrial networking products running SINEC OS, specifically the RUGGEDCOM RST2428P and SCALANCE X family switches. The vulnerability has a CVSS score of 5.5 (MEDIUM severity). CISA published this advisory on August 12, 2025, with subsequent updates through February 25, 2026, including corrections to affected product lists and clarifications on impacted configurations. The vulnerability is not listed in CISA's Known Exploited Vulnerabilities catalog.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Industrial network administrators, OT security teams, and organizations deploying Siemens RUGGEDCOM or SCALANCE switches in critical infrastructure environments should prioritize assessment. Organizations with TIPC-enabled networks in manufacturing, energy, or transportation sectors should verify exposure.
Technical summary
The vulnerability exists in the TIPC (Transparent Inter-Process Communication) protocol implementation where a crash may occur before decryption operations are completed. TIPC is a cluster communication protocol used in some industrial networking environments. The crash condition suggests improper input validation or state handling during the protocol's security processing phase. Affected products include Siemens RUGGEDCOM RST2428P (6GK6242-6PA00) and SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family switches running SINEC OS. The source threat assessment categorizes impact as 'Misinformed,' indicating potential for information disclosure or processing errors rather than direct code execution.
Defensive priority
medium
Recommended defensive actions
- Review Siemens ProductCERT advisory SSA-355557 for detailed product-specific guidance and patch availability
- Verify SINEC OS version on affected RUGGEDCOM RST2428P and SCALANCE X family devices
- Apply vendor-provided firmware updates when available per Siemens security advisory
- Monitor network traffic for anomalous TIPC protocol activity on affected industrial switches
- Implement network segmentation to limit exposure of industrial control system devices
- Follow CISA ICS recommended practices for defense-in-depth strategies
Evidence notes
CVE published 2025-08-12; modified 2026-02-25. Advisory ICSA-25-226-07 underwent four revisions, with the latest on 2026-02-25 republicating based on Siemens ProductCERT SSA-355557. Threat assessment marked as 'Misinformed' in source. Not in KEV.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-40983 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-40983
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-40983 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-40983
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-226-07.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-355557.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-355557.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.