PatchSiren cyber security CVE debrief
CVE-2024-39873 Siemens CVE debrief
A high-severity vulnerability in Siemens SINEMA Remote Connect Server allows credential brute-force attacks due to missing rate limiting on the web API authentication endpoint. Published July 9, 2024, this flaw enables network-based attackers to systematically guess user credentials without account lockout or throttling protections. The CVSS 3.1 score of 7.5 reflects high confidentiality impact with no integrity or availability impact, requiring no privileges or user interaction. Siemens has released V3.2 SP1 as a vendor fix. Organizations should prioritize patching and implement compensating network controls until remediation is complete.
- Vendor
- Siemens
- Product
- SINEMA Remote Connect Server
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-07-09
- Original CVE updated
- 2024-07-09
- Advisory published
- 2024-07-09
- Advisory updated
- 2024-07-09
Who should care
Organizations operating Siemens SINEMA Remote Connect Server for remote industrial network access; OT security teams managing VPN and remote connectivity infrastructure; critical infrastructure operators with remote maintenance requirements; security operations centers monitoring ICS authentication anomalies
Technical summary
The SINEMA Remote Connect Server web API lacks proper brute force protection mechanisms, allowing attackers to perform unlimited authentication attempts against user credentials. The vulnerability is network-exploitable with low attack complexity, requiring no privileges or user interaction. Successful exploitation results in credential disclosure with high confidentiality impact. The attack vector is the web API authentication endpoint, which fails to implement account lockout, progressive delays, or CAPTCHA protections. Exploitation has been confirmed as proof-of-concept level per the CVSS temporal metrics.
Defensive priority
high
Recommended defensive actions
- Apply vendor fix: Update SINEMA Remote Connect Server to V3.2 SP1 or later version
- Implement network-level access controls to restrict web API exposure to authorized management hosts only
- Deploy web application firewall rules to enforce rate limiting and connection throttling on authentication endpoints
- Monitor authentication logs for anomalous login patterns indicating brute force activity
- Enforce strong password policies with minimum complexity requirements to increase brute force resistance
- Consider multi-factor authentication if supported by the application to mitigate credential compromise impact
Evidence notes
CISA CSAF advisory ICSA-24-193-01 confirms the vulnerability affects SINEMA Remote Connect Server with missing brute force protection in the web API. Siemens ProductCERT advisory SSA-381581 provides the vendor fix in V3.2 SP1. CVSS vector AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C from source confirms network exploitable, low complexity, no privileges required, high confidentiality impact.
Official resources
-
CVE-2024-39873 CVE record
CVE.org
-
CVE-2024-39873 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference