A command injection vulnerability in Siemens SINEMA Remote Connect Server allows authenticated attackers to execute arbitrary code with root privileges. The flaw stems from missing server-side input sanitization when loading VxLAN configurations. Published July 9, 2024, this HIGH severity issue (CVSS 8.8) requires authentication but poses significant risk given the root-level code execution capability.
- Vendor
- Siemens
- Product
- SINEMA Remote Connect Server
- CVSS
- HIGH 8.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-07-09
- Original CVE updated
- 2024-07-09
- Advisory published
- 2024-07-09
- Advisory updated
- 2024-07-09
Who should care
Organizations operating Siemens SINEMA Remote Connect Server for remote industrial network connectivity, particularly those with externally accessible management interfaces or multi-tenant deployments where authenticated user separation is critical.
Technical summary
The vulnerability exists in the VxLAN configuration loading functionality of SINEMA Remote Connect Server. Missing server-side input sanitization allows authenticated attackers to inject arbitrary commands that execute with root privileges. The attack vector is network-accessible, requires low attack complexity, and needs valid authentication credentials. Successful exploitation grants complete system compromise.
Defensive priority
HIGH
Recommended defensive actions
- Update SINEMA Remote Connect Server to V3.2 HF1 or later version
- Restrict network access to the management interface to authorized administrative hosts only
- Monitor for unusual VxLAN configuration changes or unexpected system processes
- Apply defense-in-depth controls per CISA ICS recommended practices
- Review authentication logs for anomalous access patterns
Evidence notes
CISA ICS advisory ICSA-24-193-09 and Siemens security advisory SSA-928781 confirm the vulnerability details, affected product, and remediation path.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-39570 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-39570
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-39570 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-39570
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-09.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-928781.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-928781.html
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/pdf/ssa-928781.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/txt/ssa-928781.txt
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-09
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.