PatchSiren

PatchSiren cyber security CVE debrief

CVE-2024-39570 Siemens CVE debrief

A command injection vulnerability in Siemens SINEMA Remote Connect Server allows authenticated attackers to execute arbitrary code with root privileges. The flaw stems from missing server-side input sanitization when loading VxLAN configurations. Published July 9, 2024, this HIGH severity issue (CVSS 8.8) requires authentication but poses significant risk given the root-level code execution capability.

Vendor
Siemens
Product
SINEMA Remote Connect Server
CVSS
HIGH 8.8
CISA KEV
Not listed in stored evidence
Original CVE published
2024-07-09
Original CVE updated
2024-07-09
Advisory published
2024-07-09
Advisory updated
2024-07-09

Who should care

Organizations operating Siemens SINEMA Remote Connect Server for remote industrial network connectivity, particularly those with externally accessible management interfaces or multi-tenant deployments where authenticated user separation is critical.

Technical summary

The vulnerability exists in the VxLAN configuration loading functionality of SINEMA Remote Connect Server. Missing server-side input sanitization allows authenticated attackers to inject arbitrary commands that execute with root privileges. The attack vector is network-accessible, requires low attack complexity, and needs valid authentication credentials. Successful exploitation grants complete system compromise.

Defensive priority

HIGH

Recommended defensive actions

  • Update SINEMA Remote Connect Server to V3.2 HF1 or later version
  • Restrict network access to the management interface to authorized administrative hosts only
  • Monitor for unusual VxLAN configuration changes or unexpected system processes
  • Apply defense-in-depth controls per CISA ICS recommended practices
  • Review authentication logs for anomalous access patterns

Evidence notes

CISA ICS advisory ICSA-24-193-09 and Siemens security advisory SSA-928781 confirm the vulnerability details, affected product, and remediation path.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-39570 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-39570

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-39570 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-39570

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-09.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-928781.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-928781.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/pdf/ssa-928781.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/txt/ssa-928781.txt

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-09

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.