A buffer overflow vulnerability exists in the Linux kernel's kdb (kernel debugger) component, specifically during tab-completion of symbols. The flaw stems from incorrect use of strncpy() where the size of the source buffer is passed instead of the destination buffer. This can result in writing past the end of the command buffer when the cursor is positioned in the middle of a full buffer. The vulnerability has been resolved by replacing strncpy() calls with memmove()/memcpy() plus explicit boundary checks. Siemens has identified this as affecting SINEC OS and related industrial network infrastructure products.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Organizations operating Siemens industrial network infrastructure including SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family and SCALANCE XCM-/XRM-/XCH-/XRH-300 family switches, as well as any Linux-based systems with kdb kernel debugging enabled. System administrators responsible for OT/ICS security and patch management should prioritize this update.
Technical summary
The kdb (kernel debugger) component in the Linux kernel contains a buffer overflow vulnerability triggered during symbol tab-completion. The root cause is an incorrect strncpy() call where the source buffer size is used as the length parameter instead of the destination buffer size. When the command buffer is full and the cursor (cp) is positioned mid-buffer, this error permits writes beyond the buffer boundary. The resolution replaces strncpy() with memmove()/memcpy() operations accompanied by explicit boundary validation to ensure sufficient space exists before character manipulation. This vulnerability is classified as HIGH severity (CVSS 7.8) with local attack vector, low attack complexity, and low privileges required, enabling high impact to confidentiality, integrity, and availability.
Defensive priority
HIGH
Recommended defensive actions
- Apply vendor-provided updates to V3.1 or later for affected Siemens SINEC OS and SCALANCE products per Siemens ProductCERT advisory SSA-613116
- Review and update network segmentation for industrial control systems to limit exposure of kdb-enabled systems
- Follow CISA ICS recommended practices for defense-in-depth strategies
- Monitor for anomalous local access attempts on systems where kernel debugging may be enabled
- Validate that kernel debugging interfaces are disabled in production environments where not required
Evidence notes
The vulnerability description is drawn from the official CVE record and CISA CSAF advisory ICSA-25-226-15. The fix involves replacing strncpy() with safer memory operations and adding boundary checks. Siemens ProductCERT advisory SSA-613116 provides vendor-specific impact and remediation guidance.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-39480 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-39480
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-39480 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-39480
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-226-15.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-613116.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-613116.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-15
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.