PatchSiren cyber security CVE debrief
CVE-2024-38637 Siemens CVE debrief
A null pointer dereference vulnerability in the Linux kernel's Greybus lights subsystem could allow local attackers to cause a denial of service. The issue occurs in the get_channel_from_mode function where the return value is not validated before use in two locations. When a channel for a given node is not found, the function returns NULL, leading to a null pointer dereference if not properly checked. This vulnerability was discovered by the Linux Verification Center using SVACE static analysis. Siemens has identified this as affecting certain industrial networking products running SINEC OS, with updates available to address the issue.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- NONE
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Organizations running Siemens industrial networking equipment with SINEC OS, particularly SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family and RUGGEDCOM RST2428P switches. Linux kernel maintainers and distributors including Greybus drivers in their configurations. Industrial control system operators relying on defense-in-depth security architectures.
Technical summary
The vulnerability is located in drivers/staging/greybus/greybus-lights.c in the Linux kernel's Greybus staging driver. The get_channel_from_mode() function returns a pointer to a channel structure based on a mode node, or NULL if no matching channel exists. The original code failed to validate this return value in two call sites before dereferencing the pointer, resulting in a potential null pointer dereference. The fix adds explicit NULL checks before using the returned channel pointer. This represents a CWE-20 (Improper Input Validation) weakness. The CVSS 3.1 vector indicates network attack vector with high attack complexity, requiring no privileges but user interaction, with no impact to confidentiality, integrity, or availability in the scored configuration—though the underlying vulnerability could cause denial of service through kernel crash.
Defensive priority
medium
Recommended defensive actions
- Apply vendor-provided updates to SINEC OS V3.1 or later for affected Siemens industrial networking products
- Review Linux kernel configurations to ensure Greybus subsystem is disabled if not required for operational functionality
- Implement defense-in-depth strategies for industrial control systems per CISA recommended practices
- Monitor vendor security advisories for additional affected product families or updated remediation guidance
Evidence notes
The vulnerability exists in the Linux kernel greybus lights driver where get_channel_from_mode() can return NULL when a channel for the given node is not found. The fix adds null pointer validation before using the return value in two previously unchecked locations. Original discovery was reported via lore.kernel.org by M. Lobanov from the Linux Verification Center using SVACE static analysis tools. Siemens ProductCERT issued advisory SSA-613116 addressing this in SINEC OS-based products. CISA republished the advisory as ICSA-25-226-15 with multiple revisions through February 2026.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-38637 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-38637
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-38637 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-38637
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-226-15.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-613116.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-613116.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-15
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.