PatchSiren cyber security CVE debrief
CVE-2024-38598 Siemens CVE debrief
A vulnerability in the Linux kernel's md (Multiple Device) driver could cause a softlockup during RAID resync operations when the bitmap size is smaller than the array size. This local denial-of-service condition requires low privileges and no user interaction. Siemens has identified this vulnerability affects certain industrial networking products running SINEC OS, with a vendor fix available in version 3.1 or later. The issue was initially published on August 12, 2025, with subsequent advisory updates through February 2026 to correct affected product listings and remove rejected CVEs.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-04-09
- Original CVE updated
- 2026-05-14
- Advisory published
- 2024-04-09
- Advisory updated
- 2026-05-14
Who should care
Organizations operating Siemens industrial networking equipment with RAID configurations, particularly those in critical infrastructure sectors using SCALANCE and RUGGEDCOM product families. System administrators responsible for Linux-based industrial control systems and RAID array maintenance should prioritize this update to prevent potential denial-of-service during resync operations.
Technical summary
The vulnerability exists in the Linux kernel's md (Multiple Device) driver, specifically during RAID resync operations. When the bitmap size is configured to be smaller than the array size, the resync process can trigger a softlockup condition. This is a local vulnerability requiring low privileges with no user interaction needed. The CVSS 3.1 score of 5.5 (MEDIUM) reflects the local attack vector and high availability impact. Siemens has confirmed this affects SINEC OS running on RUGGEDCOM RST2428P and SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family devices. The fix involves proper handling of bitmap size mismatches during resync operations.
Defensive priority
medium
Recommended defensive actions
- Apply vendor fix: Update affected Siemens SINEC OS products to version 3.1 or later
- Verify RAID array configurations ensure bitmap sizing aligns with array dimensions
- Monitor system logs for softlockup indicators during resync operations on affected systems
- Review CISA ICS recommended practices for defense-in-depth strategies for industrial control systems
Evidence notes
CVE published 2025-08-12; modified 2026-02-25. Advisory ICSA-25-226-15 underwent multiple revisions: initial publication (2025-08-12), corrected affected products (2026-02-12), removed rejected CVEs (2026-02-24), and final CISA republication based on Siemens SSA-613116 (2026-02-25). CVSS 3.1 vector: AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H.
Official resources
-
CVE-2024-38598 CVE record
CVE.org
-
CVE-2024-38598 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
2025-08-12