PatchSiren cyber security CVE debrief
CVE-2024-35207 Siemens CVE debrief
A Cross-Site Request Forgery (CSRF) vulnerability exists in the web interface of Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0). An attacker can trick an authenticated victim into clicking a malicious link, enabling arbitrary actions on the device on behalf of the victim user. The vulnerability was disclosed on June 11, 2024, with a CVSS 3.1 score of 7.8 (HIGH). Siemens has released a vendor fix in version 1.2 or later.
- Vendor
- Siemens
- Product
- SINEC Traffic Analyzer (6GK8822-1BG01-0BA0)
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-06-11
- Original CVE updated
- 2025-05-06
- Advisory published
- 2024-06-11
- Advisory updated
- 2025-05-06
Who should care
Organizations operating Siemens SINEC Traffic Analyzer devices in industrial environments, particularly those with web interfaces exposed to operational networks or administrative workstations. Security teams responsible for OT/ICS infrastructure, network administrators managing industrial Ethernet diagnostics, and compliance officers tracking CVE remediation for critical infrastructure assets should prioritize this patch.
Technical summary
The web interface of Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) lacks proper CSRF protections, allowing an attacker to craft malicious requests that execute with the privileges of an authenticated victim. The attack requires user interaction (clicking a malicious link) but can result in complete compromise of device confidentiality, integrity, and availability. The CVSS 3.1 vector indicates a local attack vector with high impact across all security dimensions. Siemens has addressed this in version 1.2.
Defensive priority
HIGH
Recommended defensive actions
- Update Siemens SINEC Traffic Analyzer to version 1.2 or later
- Implement network segmentation to limit web interface access to authorized administrative hosts only
- Configure browser security policies to restrict cross-origin requests to the device web interface
- Enable and review audit logging for administrative actions performed through the web interface
- Apply defense-in-depth strategies for industrial control systems as recommended by CISA
Evidence notes
The vulnerability description and remediation details are sourced from CISA's CSAF advisory ICSA-24-165-13, which references Siemens' official security advisory SSA-196737. The CVSS vector (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) indicates local attack vector with low attack complexity, no privileges required, but user interaction required, leading to high impact on confidentiality, integrity, and availability.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-35207 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-35207
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-35207 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-35207
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-165-13.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-196737.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-196737.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-13
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.