A stack overflow vulnerability in Siemens Solid Edge, triggered by parsing maliciously crafted PAR files, allows local code execution in the context of the current process. The vulnerability was disclosed on May 14, 2024, with a CVSS 3.1 score of 7.8 (HIGH). Siemens has released a vendor fix in V224.0 Update 2.
- Vendor
- Siemens
- Product
- Solid Edge
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-05-14
- Original CVE updated
- 2024-05-14
- Advisory published
- 2024-05-14
- Advisory updated
- 2024-05-14
Who should care
Organizations using Siemens Solid Edge for computer-aided design in engineering, manufacturing, and industrial environments. Particularly relevant for operational technology (OT) environments where Solid Edge may be used in design-to-manufacturing workflows, and where defense-in-depth strategies are essential for protecting intellectual property and production systems.
Technical summary
CVE-2024-34773 is a stack overflow vulnerability in Siemens Solid Edge CAD software. The flaw exists in the PAR (part) file parsing component, where specially crafted files can trigger stack corruption. Successful exploitation allows an attacker to execute arbitrary code within the context of the current Solid Edge process. The attack requires local access and user interaction (opening a malicious file), but no privileges are required. The vulnerability carries high impact ratings for confidentiality, integrity, and availability. Siemens has addressed this in V224.0 Update 2.
Defensive priority
HIGH
Recommended defensive actions
- Apply Siemens Solid Edge V224.0 Update 2 or later to remediate this vulnerability
- Implement user awareness training to avoid opening untrusted PAR files from unknown sources
- Consider application whitelisting and least-privilege execution for Solid Edge in operational technology environments
- Monitor for anomalous Solid Edge process behavior or unexpected PAR file handling
- Review CISA ICS recommended practices for defense-in-depth strategies in industrial control system environments
Evidence notes
The vulnerability description and remediation guidance are sourced from CISA CSAF advisory ICSA-24-137-09, which references Siemens security advisory SSA-589937. The CVSS vector (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C) indicates local attack vector with user interaction required, but successful exploitation yields high impact on confidentiality, integrity, and availability.
Official resources
-
CVE-2024-34773 CVE record
CVE.org
-
CVE-2024-34773 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
2024-05-14