PatchSiren cyber security CVE debrief
CVE-2024-33489 Siemens CVE debrief
CVE-2024-33489 is a heap-based buffer overflow vulnerability in Siemens Solid Edge, a computer-aided design (CAD) application. The flaw exists in the application's parsing of specially crafted PAR (part) files. When a user opens a malicious PAR file, the vulnerability can trigger memory corruption, potentially allowing an attacker to execute arbitrary code within the context of the current process. The vulnerability was published on May 14, 2024, and carries a CVSS 3.1 score of 7.8 (HIGH severity). The attack vector is local, requiring user interaction to open a malicious file, but successful exploitation could result in complete compromise of confidentiality, integrity, and availability on the affected system.
- Vendor
- Siemens
- Product
- Solid Edge
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-05-14
- Original CVE updated
- 2024-05-14
- Advisory published
- 2024-05-14
- Advisory updated
- 2024-05-14
Who should care
Engineering organizations using Siemens Solid Edge for CAD/CAM/CAE workflows should prioritize this vulnerability. Organizations in manufacturing, aerospace, automotive, and industrial design sectors are particularly at risk due to common PAR file exchange practices. Security teams supporting OT/ICS environments with engineering workstations should include this in patch management cycles. Incident response teams should monitor for suspicious PAR file distribution as a potential attack vector against engineering supply chains.
Technical summary
The vulnerability is a heap-based buffer overflow occurring during PAR file parsing in Siemens Solid Edge. The PAR file format is used for storing 3D part geometry and feature data. Insufficient bounds checking during parsing of malformed file structures allows memory corruption. Exploitation requires social engineering to convince a user to open a malicious PAR file. Successful exploitation grants code execution with the privileges of the Solid Edge process, typically running in the context of an interactive user. The vulnerability does not require elevated privileges to trigger, but impact is constrained by the user's permissions.
Defensive priority
HIGH
Recommended defensive actions
- Apply vendor fix: Update Siemens Solid Edge to V224.0 Update 5 or later version
- Implement user awareness training to avoid opening untrusted PAR files from unknown sources
- Consider application whitelisting and endpoint protection to detect anomalous Solid Edge process behavior
- Review and restrict file sharing practices for PAR files within engineering workflows
- Monitor for suspicious Solid Edge crash events that may indicate exploitation attempts
Evidence notes
The vulnerability description and remediation guidance are derived from CISA CSAF advisory ICSA-24-137-09, which references Siemens security advisory SSA-589937. The CVSS vector (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) confirms local attack vector with user interaction required, but high impact on confidentiality, integrity, and availability.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-33489 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-33489
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-33489 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-33489
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-137-09.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-589937.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-589937.html
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/pdf/ssa-589937.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/txt/ssa-589937.txt
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-137-09
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
Methodology and review provenance