PatchSiren cyber security CVE debrief
CVE-2024-27947 Siemens CVE debrief
A medium-severity vulnerability in Siemens RUGGEDCOM CROSSBOW could allow an attacker to forward log messages to a specific compromised client under certain circumstances. The issue, published on May 14, 2024, stems from improper handling of log message forwarding that could be exploited to redirect sensitive log data to an attacker-controlled endpoint. Siemens has released version 5.5 or later to address this vulnerability. Organizations should prioritize updating affected systems and review network segmentation controls to limit exposure of industrial control system management interfaces.
- Vendor
- Siemens
- Product
- RUGGEDCOM CROSSBOW
- CVSS
- MEDIUM 5.3
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-05-14
- Original CVE updated
- 2024-05-14
- Advisory published
- 2024-05-14
- Advisory updated
- 2024-05-14
Who should care
Organizations operating Siemens RUGGEDCOM CROSSBOW centralized management systems in industrial control environments, particularly those in critical infrastructure sectors where log integrity and confidentiality are essential for security monitoring and incident response.
Technical summary
CVE-2024-27947 affects Siemens RUGGEDCOM CROSSBOW, a centralized management system for industrial network devices. The vulnerability allows log messages to be forwarded to a specific client under certain conditions, potentially enabling an attacker to exfiltrate log data to a compromised client. The CVSS 3.1 score of 5.3 reflects network accessibility, low attack complexity, and low confidentiality impact. No authentication or user interaction is required for exploitation. Siemens has addressed this issue in version 5.5 and later. The vulnerability does not appear in CISA's Known Exploited Vulnerabilities catalog, and no public exploitation has been reported at time of advisory publication.
Defensive priority
medium
Recommended defensive actions
- Update Siemens RUGGEDCOM CROSSBOW to version 5.5 or later as specified in vendor remediation guidance
- Review network segmentation to ensure management interfaces are not exposed to untrusted networks
- Monitor for anomalous log forwarding configurations or unexpected outbound connections from CROSSBOW systems
- Apply CISA ICS recommended practices for defense-in-depth strategies in industrial control environments
Evidence notes
Vulnerability description and remediation guidance sourced from CISA ICS Advisory ICSA-24-137-10, which references Siemens Security Advisory SSA-916916. CVSS 3.1 vector indicates network attack vector with low attack complexity, no privileges required, and low confidentiality impact.
Official resources
-
CVE-2024-27947 CVE record
CVE.org
-
CVE-2024-27947 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
2024-05-14