PatchSiren cyber security CVE debrief
CVE-2024-27939 Siemens CVE debrief
A critical unauthenticated arbitrary file upload vulnerability in Siemens RUGGEDCOM CROSSBOW enables remote code execution with system privileges. The vulnerability was disclosed on May 14, 2024, with a CVSS 3.1 score of 9.8. Attackers can exploit this weakness without authentication to upload malicious files and achieve full system compromise. Siemens has released version 5.5 to address this vulnerability. Organizations should prioritize patching given the unauthenticated nature of the attack vector and the high impact potential.
- Vendor
- Siemens
- Product
- RUGGEDCOM CROSSBOW
- CVSS
- CRITICAL 9.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-05-14
- Original CVE updated
- 2024-05-14
- Advisory published
- 2024-05-14
- Advisory updated
- 2024-05-14
Who should care
Organizations operating Siemens RUGGEDCOM CROSSBOW systems in industrial control system (ICS) environments, critical infrastructure operators, OT security teams, and network administrators responsible for ruggedized communication equipment in utility, transportation, and industrial sectors.
Technical summary
CVE-2024-27939 is a critical vulnerability in Siemens RUGGEDCOM CROSSBOW that permits unauthenticated users to upload arbitrary files. This weakness can be chained to achieve arbitrary code execution with system-level privileges. The vulnerability is remotely exploitable over the network without requiring authentication or user interaction. The attack complexity is low, making this vulnerability particularly dangerous for exposed systems. Siemens has addressed this issue in version 5.5, which should be deployed immediately to prevent exploitation.
Defensive priority
critical
Recommended defensive actions
- Apply Siemens RUGGEDCOM CROSSBOW update to version 5.5 or later immediately
- Restrict network access to RUGGEDCOM CROSSBOW management interfaces to authorized administrative hosts only
- Monitor for unauthorized file upload attempts and unexpected file system changes on affected systems
- Implement network segmentation to isolate RUGGEDCOM CROSSBOW systems from untrusted networks
- Review system logs for indicators of compromise, particularly around the disclosure date of May 14, 2024
Evidence notes
Vulnerability details sourced from CISA ICS advisory ICSA-24-137-10 and Siemens security advisory SSA-916916. The advisory confirms unauthenticated arbitrary file upload leading to system-level code execution. CVSS vector AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H indicates network exploitable, low attack complexity, no privileges required, no user interaction, with high impact across confidentiality, integrity, and availability.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-27939 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-27939
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-27939 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-27939
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-137-10.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-916916.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-916916.html
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/pdf/ssa-916916.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/txt/ssa-916916.txt
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-137-10
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.