A buffer overflow vulnerability exists in the Linux kernel's speakup accessibility subsystem. When a console is configured with very large dimensions and contains words exceeding 256 characters, the system fails to properly bounds-check input before writing to a fixed-size word buffer, leading to a crash condition. This vulnerability was resolved in the Linux kernel by implementing proper length validation to prevent writes beyond the buffer boundary. Siemens has identified this vulnerability as affecting certain industrial networking products that incorporate the vulnerable kernel code, with a vendor fix available requiring update to version 3.1 or later.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- MEDIUM 5.9
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
System administrators managing Linux-based industrial control systems and network infrastructure; security teams responsible for operational technology environments; accessibility technology deployers using speakup on large-console configurations; Siemens industrial networking equipment operators; organizations subject to CISA ICS security guidance
Technical summary
CVE-2024-26994 is a buffer overflow vulnerability in the Linux kernel's speakup screen reader subsystem. The vulnerability occurs when processing console output containing words longer than 256 characters on consoles with large dimensions. The speakup subsystem, which provides accessibility features for visually impaired users, uses a fixed-size word buffer that can be overflowed when processing exceptionally long words without proper bounds validation. This results in memory corruption and system crash. The vulnerability has been resolved in the Linux kernel through implementation of proper length checking to prevent buffer overflow. Siemens has identified affected products in their SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family, SCALANCE XCM-/XRM-/XCH-/XRH-300 family, and RUGGEDCOM RST2428P industrial networking equipment, with remediation requiring firmware update to version 3.1 or later.
Defensive priority
medium
Recommended defensive actions
- Apply vendor-provided firmware updates to version 3.1 or later for affected Siemens SCALANCE and RUGGEDCOM products per Siemens ProductCERT guidance
- Review console configurations on affected systems to identify any non-standard large console dimension settings that may increase exposure
- Implement network segmentation for industrial control systems to limit access to device management interfaces
- Monitor for anomalous system crashes or accessibility subsystem failures that may indicate exploitation attempts
- Follow CISA ICS recommended practices for defense-in-depth strategies for industrial control systems
Evidence notes
The vulnerability description indicates a classic buffer overflow scenario in kernel-space accessibility code. The speakup subsystem provides screen reader functionality for visually impaired users, processing console output character by character. The 256-character threshold suggests a fixed-size stack or static buffer allocation. The fix implements bounds checking to truncate or reject over-length input rather than permitting memory corruption. Siemens ProductCERT advisory SSA-613116 provides the authoritative vendor assessment for affected industrial control system products.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-26994 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-26994
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-26994 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-26994
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-226-15.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-613116.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-613116.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-15
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.