PatchSiren cyber security CVE debrief
CVE-2024-26982 Siemens CVE debrief
CVE-2024-26982 is a HIGH-severity Linux kernel Squashfs issue referenced in Siemens advisory ICSA-25-072-03 for SIMATIC S7-1500 TM MFP - BIOS. The published advisory describes the flaw as a missing check to ensure an inode number is not the invalid value of zero. The supplied CVSS vector indicates a local attack path with low privileges and no user interaction, and the advisory states that no fix is currently available.
- Vendor
- Siemens
- Product
- SIMATIC S7-1500 TM MFP - BIOS
- CVSS
- HIGH 7.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-04-09
- Original CVE updated
- 2026-05-14
- Advisory published
- 2024-04-09
- Advisory updated
- 2026-05-14
Who should care
Organizations that use or manage Siemens SIMATIC S7-1500 TM MFP - BIOS should review the advisory, especially teams responsible for industrial control systems, embedded platforms, and any local software deployment or maintenance workflows on affected equipment. Security teams should also pay attention because the issue is local and low-privilege, which can matter where multiple users or maintenance access exist.
Technical summary
The source corpus ties CVE-2024-26982 to a Linux kernel Squashfs validation defect: the inode number was not being checked against the invalid value zero. The advisory provides a CVSS 3.1 vector of AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H, indicating a locally reachable issue requiring low privileges and no user interaction, with high confidentiality and availability impact. The Siemens advisory also states that no fix is available at the time of publication.
Defensive priority
High for affected Siemens deployments, because the advisory lists no available fix and the vulnerability can be exercised locally with low privileges. Prioritize exposure review, access control hardening, and operational safeguards until Siemens provides a remediation path.
Recommended defensive actions
- Confirm whether your environment includes Siemens SIMATIC S7-1500 TM MFP - BIOS systems referenced by ICSA-25-072-03.
- Restrict and monitor local access on affected systems, since the CVSS vector requires local access and low privileges.
- Follow Siemens/CISA advisory guidance and track for a future remediation update, because the advisory states that no fix is currently available.
- Apply defense-in-depth controls for industrial systems, including least privilege, trusted software sources, and strict change control.
- Review maintenance, build, and deployment workflows to ensure only trusted applications and artifacts are used on affected platforms.
Evidence notes
This debrief is based only on the supplied CISA CSAF advisory metadata and linked official references. The advisory title is Siemens SIMATIC S7-1500 TM MFP - BIOS, the description states the Linux kernel Squashfs inode-zero validation issue, the CVSS vector is AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H, and the remediation section says no fix is currently available with a workaround to use trusted sources. No KEV entry or ransomware-campaign linkage is provided in the supplied corpus.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-26982 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-26982
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-26982 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-26982
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-072-03.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-503939.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-503939.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-03
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance