PatchSiren cyber security CVE debrief
CVE-2024-26684 Siemens CVE debrief
This CVE addresses a vulnerability in the Linux kernel's stmmac (Synopsys DesignWare Ethernet MAC) driver, specifically within the XGMAC (10 Gigabit Ethernet MAC) implementation. The issue involves improper handling of DPP (Data Path Protection) safety errors for DMA channels. DPP is a safety mechanism designed to detect and handle errors in data transmission paths. When this safety error handling fails, it could lead to system instability or potential security implications in network data processing. The vulnerability was resolved through a kernel patch that corrects the DPP safety error handling logic for DMA channels in the XGMAC driver.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- Unknown
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Organizations operating Siemens industrial Ethernet infrastructure including SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family, SCALANCE XCM-/XRM-/XCH-/XRH-300 family, and RUGGEDCOM RST2428P switches. OT security teams managing Linux-based embedded systems with Synopsys DesignWare Ethernet MAC controllers should also assess exposure.
Technical summary
The vulnerability exists in the Linux kernel's stmmac Ethernet driver, specifically the XGMAC (10 Gigabit Ethernet MAC) implementation's handling of DPP (Data Path Protection) safety errors for DMA channels. DPP mechanisms are designed to detect data path integrity issues; improper handling of these errors could result in undefined behavior during network operations. The fix ensures proper error handling paths are executed when DPP safety errors are detected in DMA channel operations.
Defensive priority
medium
Recommended defensive actions
- Review Siemens ProductCERT advisory SSA-613116 for specific patch availability and version guidance for affected SCALANCE and RUGGEDCOM products
- Apply vendor-provided firmware updates for affected Siemens industrial Ethernet switches when available
- Monitor network device logs for anomalous DMA or Ethernet MAC related errors that could indicate trigger conditions
- Implement network segmentation for critical industrial control systems using affected devices
- Follow CISA's ICS recommended practices for defense-in-depth strategies in industrial environments
Evidence notes
The vulnerability description indicates this was a resolved issue in the Linux kernel's network driver subsystem. The source advisory (ICSA-25-226-15) from CISA's CSAF repository identifies affected Siemens industrial networking products that incorporate the vulnerable kernel component. The advisory's revision history shows ongoing refinement of affected product lists, with corrections made in February 2026 to accurately reflect impacted systems.
Official resources
-
CVE-2024-26684 CVE record
CVE.org
-
CVE-2024-26684 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
2025-08-12