PatchSiren cyber security CVE debrief
CVE-2023-52810 Siemens CVE debrief
This CVE addresses a vulnerability in the Linux kernel's Journaled File System (JFS) implementation. The issue involved a missing validation check for negative values of the `db_l2nbperpage` parameter, which could lead to undefined behavior or system instability. The vulnerability was resolved by adding an explicit check to prevent negative values from being processed. Siemens has identified this CVE as affecting certain industrial networking products, specifically the RUGGEDCOM RST2428P and SCALANCE X family devices running SINEC OS, with the threat assessment categorized as 'Misinformed' per the CSAF advisory. The advisory was initially published on August 12, 2025, and subsequently updated on February 25, 2026, to reflect corrections to affected product listings and removal of unsupported product versions. No CVSS score or severity rating is available in the source corpus. This vulnerability is not listed in CISA's Known Exploited Vulnerabilities (KEV) catalog.
- Vendor
- Siemens
- Product
- RUGGEDCOM RST2428P (6GK6242-6PA00)
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-08-12
- Original CVE updated
- 2026-02-25
- Advisory published
- 2025-08-12
- Advisory updated
- 2026-02-25
Who should care
Organizations operating Siemens industrial networking equipment including RUGGEDCOM RST2428P switches and SCALANCE X family devices (XC-300/XR-300/XC-400/XR-500WG/XR-500, XCM-/XRM-/XCH-/XRH-300 families) running SINEC OS. System administrators responsible for industrial control system security and Linux kernel maintainers should monitor for applicable patches.
Technical summary
The vulnerability exists in the Linux kernel's JFS (Journaled File System) implementation where the `db_l2nbperpage` parameter was not validated for negative values. This parameter, which represents the logarithm base 2 of the number of blocks per page, could potentially be set to a negative value leading to incorrect memory calculations or filesystem corruption. The resolution adds an explicit bounds check to reject negative values before they are used in subsequent calculations. This is a defensive coding fix that prevents potential integer-related issues in filesystem operations.
Defensive priority
medium
Recommended defensive actions
- Review Siemens ProductCERT advisory SSA-613116 for detailed product-specific guidance
- Verify SINEC OS version on affected SCALANCE and RUGGEDCOM devices
- Apply vendor-provided patches or updates as specified in Siemens security advisory
- Monitor CISA ICS advisories for additional guidance on industrial control system security practices
- Implement defense-in-depth strategies for industrial control systems per CISA recommended practices
Evidence notes
The vulnerability description indicates a kernel-level filesystem validation fix. Siemens CSAF advisory ICSA-25-226-15 tracks this CVE with threat category 'Misinformed' for affected product IDs. The advisory underwent four revision cycles, with the most recent update on February 25, 2026, removing unsupported SINEC OS versions and rejected CVEs from the advisory scope.
Sources and references
Verified primary and authoritative sources
-
CVE-2023-52810 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2023-52810
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2023-52810 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2023-52810
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-226-15.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-613116.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-613116.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-15
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.