PatchSiren

PatchSiren cyber security CVE debrief

CVE-2023-2269 Siemens CVE debrief

A denial-of-service vulnerability exists in the Linux Kernel Device Mapper-Multipathing sub-component, specifically within the `table_clear` function in `drivers/md/dm-ioctl.c`. The issue stems from a possible recursive locking scenario that can result in a deadlock. This vulnerability affects Siemens SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) and TIM 1531 IRC (6GK7543-1MX00-0XE0) devices. The CVSS v3.1 score of 4.4 (MEDIUM) reflects local attack vector, low attack complexity, high privileges required, and high availability impact. CISA published advisory ICSA-24-165-06 on June 11, 2024, with a subsequent update on July 9, 2024. Siemens has released firmware version V2.4.8 or later to address this vulnerability.

Vendor
Siemens
Product
SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)
CVSS
MEDIUM 4.4
CISA KEV
Not listed in stored evidence
Original CVE published
2023-04-25
Original CVE updated
2026-10-08
Advisory published
2023-04-25
Advisory updated
2026-10-08

Who should care

Organizations operating Siemens TIM 1531 IRC industrial communication modules in critical infrastructure environments, including manufacturing, energy, and process control sectors. System administrators responsible for firmware lifecycle management in OT/ICS environments should prioritize this update.

Technical summary

The vulnerability resides in the `table_clear` function within `drivers/md/dm-ioctl.c` of the Linux Kernel Device Mapper-Multipathing sub-component. A recursive locking scenario can trigger a deadlock condition, resulting in denial of service. The attack requires local access and high privileges (PR:H), limiting exploitability. The vulnerability was addressed in Siemens firmware V2.4.8.

Defensive priority

medium

Recommended defensive actions

  • Apply vendor-provided firmware update to version V2.4.8 or later for affected Siemens TIM 1531 IRC devices
  • Verify current firmware version on SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) and TIM 1531 IRC (6GK7543-1MX00-0XE0) installations
  • Implement network segmentation for industrial control systems to limit exposure of affected devices
  • Follow CISA ICS recommended practices for defense-in-depth strategies
  • Monitor Siemens ProductCERT portal for additional security updates related to SSA-337522

Evidence notes

The vulnerability description and affected products are derived from CISA CSAF source ICSA-24-165-06. CVSS vector CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C confirms local attack vector with high privileges required. Remediation guidance specifies firmware update to V2.4.8 or later.

Sources and references

Verified primary and authoritative sources

  • CVE-2023-2269 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2023-2269

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2023-2269 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2023-2269

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-165-06.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/csaf/ssa-337522.json

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/html/ssa-337522.html

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/pdf/ssa-337522.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://cert-portal.siemens.com/productcert/txt/ssa-337522.txt

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-06

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.