PatchSiren cyber security CVE debrief
CVE-2023-0160 Siemens CVE debrief
A deadlock vulnerability in the Linux kernel's BPF subsystem affects Siemens TIM 1531 IRC industrial communication devices. The flaw allows a local attacker to trigger a system crash through the BPF subsystem's deadlock condition. Siemens has released firmware version 2.4.8 to address this issue.
- Vendor
- Siemens
- Product
- SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-02-13
- Original CVE updated
- 2024-02-13
- Advisory published
- 2024-02-13
- Advisory updated
- 2024-02-13
Who should care
Organizations operating Siemens TIM 1531 IRC industrial communication devices in manufacturing, energy, and critical infrastructure environments should prioritize this update. System administrators responsible for industrial control system (ICS) security, OT security teams, and asset owners with deployed Siemens industrial networking equipment should assess exposure and apply the vendor fix.
Technical summary
CVE-2023-0160 is a deadlock vulnerability in the Linux kernel's Berkeley Packet Filter (BPF) subsystem. The flaw exists in the BPF verifier and program loading mechanisms where improper locking can lead to a deadlock condition. A local user with appropriate privileges can exploit this to cause a system crash, resulting in denial of service. The vulnerability affects Siemens SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) and TIM 1531 IRC (6GK7543-1MX00-0XE0) industrial communication modules, which utilize embedded Linux systems. The CVSS 3.1 score of 5.5 (MEDIUM) reflects the local attack vector and high availability impact with no confidentiality or integrity impact.
Defensive priority
medium
Recommended defensive actions
- Update affected Siemens TIM 1531 IRC devices to firmware version 2.4.8 or later
- Apply vendor-provided patches through Siemens Industry Online Support portal
- Implement network segmentation for industrial control systems per CISA recommended practices
- Monitor for anomalous local access attempts on affected devices
- Review and apply defense-in-depth strategies for industrial control environments
Evidence notes
The vulnerability was disclosed in CISA advisory ICSA-24-165-06 on June 11, 2024, with a subsequent update on July 9, 2024. The advisory references Siemens security advisory SSA-337522. The CVSS 3.1 vector (AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H) confirms local attack vector with low attack complexity and high availability impact.
Sources and references
Verified primary and authoritative sources
-
CVE-2023-0160 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2023-0160
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2023-0160 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2023-0160
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-165-06.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-337522.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-337522.html
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/pdf/ssa-337522.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/txt/ssa-337522.txt
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-165-06
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.