PatchSiren cyber security CVE debrief
CVE-2021-3506 Siemens CVE debrief
An out-of-bounds memory access vulnerability in the Linux kernel's f2fs filesystem module affects 26 Siemens SCALANCE and RUGGEDCOM industrial networking products. The flaw, located in fs/f2fs/node.c in kernel versions before 5.12.0-rc4, stems from a bounds check failure that allows local attackers to access out-of-bounds memory. This can result in system crashes or information disclosure from internal kernel memory. The vulnerability requires local access with low privileges, no user interaction, and poses a high threat to system availability. Siemens has released firmware updates to address this issue.
- Vendor
- Siemens
- Product
- RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
- CVSS
- HIGH 7.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2021-04-19
- Original CVE updated
- 2026-09-01
- Advisory published
- 2021-04-19
- Advisory updated
- 2026-09-01
Who should care
Industrial control system operators, OT security teams, and network administrators managing Siemens SCALANCE or RUGGEDCOM infrastructure in manufacturing, energy, transportation, and critical infrastructure sectors. Organizations with remote access to industrial networks or shared local access environments face elevated risk.
Technical summary
The vulnerability exists in the Flash-Friendly File System (f2fs) node management code within the Linux kernel. A bounds check failure in fs/f2fs/node.c permits out-of-bounds memory reads when processing f2fs filesystem structures. The attack vector is local, requiring low privileges but no user interaction. Successful exploitation can cause denial of service through system crashes or leak sensitive kernel memory contents. The CVSS 3.1 vector AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H reflects local attack complexity with high impacts to confidentiality and availability. Siemens has addressed this in firmware version 8.2 across affected SCALANCE M804PB, M812-1, M816-1, M826-2, M874-2, M874-3, M876-3, M876-4, MUM853-1, MUM856-1, S615, and RUGGEDCOM RM1224 product lines.
Defensive priority
high
Recommended defensive actions
- Apply vendor firmware updates to version 8.2 or later for all affected SCALANCE and RUGGEDCOM devices
- Verify current firmware version through Siemens Industry Online Support portal
- Implement network segmentation to limit local access to industrial control devices
- Monitor for anomalous system crashes or unexpected reboots on affected devices
- Review CISA ICS recommended practices for defense-in-depth strategies
- Subscribe to Siemens ProductCERT security advisories for future vulnerability notifications
Evidence notes
CVE published 2024-11-12 per CISA CSAF advisory ICSA-24-319-06. Modified 2025-05-06. Advisory references Siemens SSA-354112 for original vendor disclosure. 26 affected products across SCALANCE M-800 family, RUGGEDCOM RM1224, and SCALANCE S615 lines identified in CSAF product tree.
Sources and references
Verified primary and authoritative sources
-
CVE-2021-3506 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2021-3506
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2021-3506 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2021-3506
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-319-06.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/csaf/ssa-354112.json
Reference
-
Source reference
Unverified legacy reference
URL: https://cert-portal.siemens.com/productcert/html/ssa-354112.html
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-319-06
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.