CVE-2026-9716 Schneider Electric CVE debrief

CVE-2026-9716 is a high-severity vulnerability in Schneider Electric's PowerLogic P7 device. A NULL pointer dereference could allow an attacker to cause a denial-of-service condition, rendering the device's HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces. The vulnerability has a CVSS score of 8.7 and is considered HIGH severity. Schneider Electric has provided a vendor advisory with mitigation details. Users should review and apply the recommended mitigations to prevent potential exploitation.

Vendor
Schneider Electric
Product
PowerLogicâ„¢ P7
CVSS
HIGH 8.7
CISA KEV
Not listed in stored evidence
Original CVE published
2026-06-25
Original CVE updated
2026-07-01
Advisory published
2026-06-25
Advisory updated
2026-07-01

Who should care

Organizations using Schneider Electric's PowerLogic P7 device should prioritize patching this vulnerability. The device's exposure to the internet or untrusted networks increases the risk of exploitation. Reviewing network configurations and applying vendor-provided mitigations can help prevent potential denial-of-service conditions.

Technical summary

CVE-2026-9716 is a CWE-476 NULL Pointer Dereference vulnerability in Schneider Electric's PowerLogic P7 device. The vulnerability exists due to improper handling of malformed requests over exposed network interfaces. An attacker could exploit this vulnerability to cause a denial-of-service condition, making the device's HMI and configuration functionality unavailable. The CVSS vector for this vulnerability is CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X.

Defensive priority

High priority should be given to patching CVE-2026-9716 due to its high CVSS score and potential impact on device availability. Organizations should review their inventory of PowerLogic P7 devices and apply the vendor-provided mitigations to prevent potential exploitation.

Recommended defensive actions

  • Review and apply the vendor-provided mitigations as outlined in the Schneider Electric advisory.
  • Conduct an inventory check to identify and prioritize PowerLogic P7 devices that require patching.
  • Limit exposure of PowerLogic P7 devices to untrusted networks and the internet.
  • Monitor network traffic and device logs for signs of potential exploitation attempts.
  • Implement compensating controls, such as network segmentation and access controls, to reduce the attack surface.

Evidence notes

The CVE-2026-9716 vulnerability is documented in the official CVE record and NVD detail pages. Schneider Electric has provided a vendor advisory with mitigation details. The vulnerability has a CVSS score of 8.7 and is considered HIGH severity. The CWE-476 NULL Pointer Dereference vulnerability could allow an attacker to cause a denial-of-service condition.