A CVE-2026-13336 debrief based on the supplied source corpus. The vulnerability is an OS command injection issue in NetBotz 5 750 and 755 systems, which could allow execution of Linux operating system commands when a maliciously modified system backup is restored. The vulnerability has a CVSS v4.0 Base Score of 7.3 and is considered High severity. Defenders should assess exposure, verify backup integrity, and apply the vendor-provided fix to prevent potential Linux command execution. This CVE was published on 2026-08-11T07:00:00.000Z and has not been modified since then.
- Vendor
- Schneider Electric
- Product
- NetBotz 5 750
- CVSS
- MEDIUM 6.4
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-08-11
- Original CVE updated
- 2026-09-17
- Advisory published
- 2026-08-11
- Advisory updated
- 2026-09-17
Who should care
Defenders responsible for Schneider Electric NetBotz 5 750 and 755 systems, especially those with versions 5.5.2 and prior, should assess exposure and verify the integrity of system backups.
Why it matters
CVE-2026-13336 is an OS command injection vulnerability in NetBotz 5 750 and 755 systems. Defenders should verify exposure, assess backup integrity, and apply the vendor-provided fix to prevent potential Linux command execution.
- Verify exposure of affected NetBotz systems.
- Assess integrity of system backups.
- Apply vendor-provided fix version 5.6.0.
- Monitor for potential malicious backup modifications.
Technical summary
The CVE-2026-13336 vulnerability is an OS command injection issue in NetBotz 5 750 and 755 systems, which could allow execution of Linux operating system commands when a maliciously modified system backup is restored. The vulnerability has a CVSS v4.0 Base Score of 7.3 and is considered High severity. Affected systems include NetBotz 5 750 and 755, especially those with versions 5.5.2 and prior. Defenders should prioritize verifying exposure and assessing the integrity of system backups. The vendor-provided fix, version 5.6.0, should be applied to prevent potential Linux command execution.
Defensive priority
Defenders should prioritize verifying exposure of NetBotz 5 750 and 755 systems, especially those with versions 5.5.2 and prior, and assess the integrity of system backups.
Recommended defensive actions
- Verify exposure of NetBotz 5 750 and 755 systems, especially those with versions 5.5.2 and prior.
- Assess the integrity of system backups.
- Apply the vendor-provided fix, version 5.6.0, for NetBotz 5 750/755.
- Monitor system backups for potential malicious modifications.
- Review compensating controls for exposed systems while remediation is scheduled and verified.
- Check relevant monitoring, detection, and logs for exposed assets that need extra review.
- Track exceptions, retest remediated assets, and close the item only after evidence is documented.
Evidence notes
The CVE record and source item provide details on the OS command injection vulnerability in NetBotz 5 750 and 755 systems. Evidence is based on official CVE and CISA CSAF records. The vulnerability affects NetBotz 5 750 and 755 systems, especially those with versions 5.5.2 and prior. Defenders should verify exposure and assess the integrity of system backups. The CVE has a CVSS v4.0 Base Score of 7.3, indicating High severity. The vendor-provided fix, version 5.6.0, should be applied to prevent potential Linux command execution.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-13336 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-13336
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-13336 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-13336
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
CVE-2026-13336
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-260-05.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.se.com/ww/en/download/document/7EN52-0390/
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-260-05
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.