PatchSiren cyber security CVE debrief
CVE-2026-21162 Samsung Mobile CVE debrief
CVE-2026-21162 is an out-of-bounds write vulnerability in libiosotglib.so prior to version 3.7.73.4. This vulnerability allows physical attackers to execute arbitrary code, requiring user interaction to trigger. The vulnerability affects Samsung Mobile Smart Switch devices. Defenders should prioritize patching and user education to prevent exploitation. Physical security measures should also be implemented to prevent unauthorized access to devices. The CVE Program and NVD provide official records and assessments of this vulnerability.
- Vendor
- Samsung Mobile
- Product
- Smart Switch
- CVSS
- MEDIUM 5.2
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-11-16
- Original CVE updated
- 2026-11-16
- Advisory published
- 2026-11-16
- Advisory updated
- 2026-11-16
Who should care
Defenders responsible for physical security, user education, and patch management for Samsung Mobile Smart Switch devices should prioritize this vulnerability. They should review and apply the vendor-provided patch for version 3.7.73.4 or later. Implementing physical security measures and educating users on secure interactions with devices are also crucial. Additionally, defenders should consider compensating and .
Why it matters
CVE-2026-21162 is a medium-severity vulnerability in Samsung Mobile Smart Switch that requires physical access and user interaction to execute arbitrary code. Defenders should prioritize patching and user education to prevent exploitation.
- Physical attackers can execute arbitrary code with user interaction
- User education is required to prevent exploitation
- Patch management is crucial to prevent exploitation
Technical summary
The vulnerability is an out-of-bounds write in libiosotglib.so prior to version 3.7.73.4, allowing physical attackers to execute arbitrary code. User interaction is required to trigger this vulnerability. The affected product is Samsung Mobile Smart Switch. Defenders should focus on patch management and user education to prevent exploitation. Physical security measures should also be implemented.
Defensive priority
Medium priority for physical security and user interaction validation
Recommended defensive actions
- Review and apply the vendor-provided patch for version 3.7.73.4 or later
- Implement physical security measures to prevent unauthorized access to devices
- Educate users on the importance of secure interactions with devices
Evidence notes
The vulnerability is described in the CVE record and the GitHub advisory database. The CVE Program and NVD provide official records and assessments. Evidence is limited to public sources and may not be comprehensive. Defenders should verify affected scope and vendor guidance. Additional details may be found in vendor documentation and security advisories.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-21162 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-21162
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-21162 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-21162
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Out-of-bounds write in libiosotglib.so prior to version 3.7.73.4 allows physical attackers to...
Unverified legacy reference
URL: https://github.com/advisories/GHSA-7r95-w87g-wm7r
github_advisory_database
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.