PatchSiren cyber security CVE debrief
CVE-2025-53078 Samsung Electronics CVE debrief
CVE-2025-53078 is a Samsung HVAC DMS issue disclosed in CISA advisory ICSA-25-210-02 on 2025-07-29. The advisory states that deserialization of untrusted data in Samsung DMS (Data Management Server) can allow attackers to execute arbitrary code via write-file-to-system behavior. CISA’s advisory lists three affected version ranges and recommends updating through Samsung support and keeping the product on a separate dedicated network, disconnected from the Internet.
- Vendor
- Samsung Electronics
- Product
- Samsung HVAC DMS
- CVSS
- HIGH 8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-07-29
- Original CVE updated
- 2025-07-29
- Advisory published
- 2025-07-29
- Advisory updated
- 2025-07-29
Who should care
Organizations running Samsung HVAC DMS in industrial, facilities, or OT-adjacent environments should review this immediately, especially if the system is reachable from other networks or the Internet. System integrators and operators responsible for maintaining these deployments should also verify version status and mitigation steps.
Technical summary
The advisory describes a deserialization-of-untrusted-data weakness in Samsung DMS (Data Management Server). CISA lists these affected ranges: Samsung HVAC DMS >=2.0.0 and <2.3.13.0; >=2.5.0.17 and <2.6.14.0; and >=2.7.0.15 and <2.9.3.5. The provided CVSS vector is CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H, corresponding to a HIGH severity score of 8.0. The remediation guidance states the product is not intended to be connected to the Internet and should remain on a separate dedicated network.
Defensive priority
High. The advisory indicates code-execution impact on affected Samsung HVAC DMS versions, and the vendor/CISA guidance calls for both updating and network isolation.
Recommended defensive actions
- Confirm whether any Samsung HVAC DMS instance is running an affected version range: 2.0.0-<2.3.13.0, 2.5.0.17-<2.6.14.0, or 2.7.0.15-<2.9.3.5.
- Contact a Samsung call center or installer to obtain and apply the recommended software update.
- Disconnect affected systems from the Internet and keep them on a separate dedicated network, per the advisory and product manual statement.
- Review network exposure and reduce access paths to the DMS until updates are applied.
- Document remediation status for OT/facilities asset inventories and track the advisory ICSA-25-210-02 for any follow-up revisions.
Evidence notes
All factual claims are drawn from the supplied CISA CSAF advisory and its embedded remediation guidance. The advisory date used here is the published/modified date provided in the source data: 2025-07-29T06:00:00.000Z. No KEV entry was supplied for this CVE. The CVSS vector and affected version ranges are taken directly from the advisory metadata.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-53078 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-53078
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-53078 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-53078
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-210-02.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-210-02
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.