PatchSiren cyber security CVE debrief
CVE-2026-30802 RTI CVE debrief
CVE-2026-30802 is a high-severity Out-of-bounds Read vulnerability in RTI Connext Micro (Core Libraries). The issue allows for Overread Buffers and affects Connext Micro versions from 4.0.0 before 4.3.0. With a CVSS score of 8.8, this vulnerability poses a significant risk. Users of affected versions should take immediate action to mitigate potential threats. RTI has provided information on this vulnerability on their website. The CVE was published on June 17, 2026, and last modified on the same day.
- Vendor
- RTI
- Product
- Connext Micro
- CVSS
- HIGH 8.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-06-17
- Original CVE updated
- 2026-06-17
- Advisory published
- 2026-06-17
- Advisory updated
- 2026-06-17
Who should care
Organizations using RTI Connext Micro (Core Libraries) versions 4.0.0 through 4.2.0 should prioritize patching this vulnerability. Given the high CVSS score of 8.8, this issue is critical for teams responsible for maintaining systems that utilize this software. The vulnerability's impact could lead to significant disruptions if exploited.
Technical summary
The CVE-2026-30802 vulnerability is classified as an Out-of-bounds Read issue within RTI Connext Micro (Core Libraries). This type of vulnerability typically occurs when a program attempts to read data from or write data to an incorrect location in memory, leading to potential crashes or data leakage. The specific weakness associated with this CVE is CWE-125. The vulnerability has been assessed with a CVSS score of 8.8, indicating a high level of severity. The vector CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X provides a detailed breakdown of the vulnerability's characteristics.
Defensive priority
High
Recommended defensive actions
- Apply the patch or update to RTI Connext Micro version 4.3.0 or later.
- Review and restrict network access to affected systems.
- Monitor systems for unusual activity.
- Implement additional security measures such as intrusion detection systems.
- Regularly update and patch all software components.
- Consider isolating critical systems.
- Engage with RTI support for further guidance.
Evidence notes
The information provided is based on data from the NVD and CVE.org. The CVE was published and last modified on June 17, 2026. RTI has provided a reference for this vulnerability on their website.
Official resources
-
CVE-2026-30802 CVE record
CVE.org
-
CVE-2026-30802 NVD detail
NVD
-
Source item URL
nvd_modified
-
Source reference
3f572a00-62e2-4423-959a-7ea25eff1638
This debrief is based on publicly available information from official sources.