PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-124759 RT-Labs CVE debrief

A host with ADJACENT network access can abort an established Application Relationship with a single alarm ERROR frame, or deliver forged alarm notifications with chosen type, slot, subslot, USI and payload to the application in P-Net before 1.0.4. This vulnerability impacts application relationships, potentially disrupting functionality, and requires verification of network access controls and monitoring. Defenders should assess exposure and prioritize verification to mitigate potential operational impacts.

Vendor
RT-Labs
Product
P-Net
CVSS
HIGH 7.1
CISA KEV
Not listed in stored evidence
Original CVE published
2026-11-13
Original CVE updated
2026-11-17
Advisory published
2026-11-13
Advisory updated
2026-11-17

Who should care

Defenders responsible for network access control, monitoring, and P-Net application security should assess exposure and prioritize verification. This includes operators, platform administrators, vulnerability management teams, and security teams who need to review and update P-Net to version 1.0.4 or later. They should also verify network access controls, monitor for suspicious alarm activity, and review compensating controls for exposed systems.

Why it matters

CVE-2026-124759 allows adjacent network access to abort or forge alarm notifications in P-Net before 1.0.4, impacting application relationships and potentially disrupting functionality.

  • Aborting established Application Relationships
  • Delivering forged alarm notifications
  • Potential disruption of application functionality
  • Need for verification of network access controls and monitoring

Technical summary

P-Net before 1.0.4 routes a received RTA alarm frame to an Application Relationship using only the destination alarm reference in the frame, without checking the source of the frame. This allows adjacent network access to abort or forge alarm notifications, impacting application relationships and potentially disrupting functionality. The vulnerability requires verification of network access controls and monitoring to mitigate potential operational impacts. Affected product deployments should be identified and assessed for exposure.

Defensive priority

Defenders should prioritize verifying network access controls and monitoring for suspicious alarm activity.

Recommended defensive actions

  • Verify network access controls to prevent adjacent network access
  • Monitor for suspicious alarm activity
  • Review and update P-Net to version 1.0.4 or later
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented

Evidence notes

The source item from github_advisory_database provides details on the vulnerability, while the CVE Program record and NVD vulnerability detail offer additional context. Evidence limits suggest that further verification is needed to confirm affected scope and severity. Defenders should verify network access controls, monitor for suspicious alarm activity, and review P-Net version.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-124759 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-124759

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-124759 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-124759

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.