PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-9637 Rockwell Automation CVE debrief

A denial-of-service vulnerability exists in Rockwell Automation's Logix platforms due to improper validation of input length during CIP message processing. This can result in a major nonrecoverable fault (MNRF), requiring a power cycle to recover. The vulnerability affects Rockwell Automation ControlLogix 5580, CompactLogix 5380, and GuardLogix 5580 devices. Operators and administrators should assess exposure and prioritize verification of inventory, especially for versions V33 and earlier.

Vendor
Rockwell Automation
Product
ControlLogix 5580
CVSS
HIGH 7.5
CISA KEV
Not listed in stored evidence
Original CVE published
2026-09-01
Original CVE updated
2026-09-01
Advisory published
2026-09-01
Advisory updated
2026-09-01

Who should care

Operators and administrators of Rockwell Automation ControlLogix 5580, CompactLogix 5380, and GuardLogix 5580 devices should assess exposure and prioritize verification of inventory.

Why it matters

CVE-2026-9637 is a denial-of-service vulnerability in Rockwell Automation Logix platforms. Operators and administrators of affected devices should assess exposure, verify inventory, and apply updates to mitigate risk.

  • Denial-of-service attacks could disrupt operational technology (OT) environments
  • Faults may require manual intervention to recover
  • Inventory verification and patching are necessary to mitigate risk
  • Remediation requires updates to specific firmware versions

Technical summary

The vulnerability exists in Rockwell Automation's Logix platforms due to improper validation of input length during CIP message processing, potentially causing a major nonrecoverable fault (MNRF) that requires a power cycle to recover. Affected versions include ControlLogix 5580, CompactLogix 5380, and GuardLogix 5580 devices. The vulnerability can be mitigated by applying firmware updates to specific versions and implementing Rockwell Automation's security best practices for industrial control systems. Operators and administrators should assess exposure and prioritize verification of inventory.

Defensive priority

Operators and administrators of Rockwell Automation ControlLogix 5580, CompactLogix 5380, and GuardLogix 5580 devices should assess exposure and prioritize verification of inventory, especially for versions V33 and earlier, and apply updates if available.

Recommended defensive actions

  • Verify inventory of Rockwell Automation ControlLogix 5580, CompactLogix 5380, and GuardLogix 5580 devices
  • Assess exposure for versions V33 and earlier
  • Apply firmware updates to version V37.011 for ControlLogix 5580, CompactLogix 5380, and GuardLogix 5580; version 34.015 for versions 34.011-34.014; version 35.014 for versions 35.011-35.013; and version 36.013 for 36.011
  • Implement Rockwell Automation's security best practices for industrial control systems as a compensating control for those unable to upgrade immediately
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented

Evidence notes

The vulnerability allows for denial-of-service attacks by improper validation of CIP message input length, potentially causing a major nonrecoverable fault. Affected versions and specific remediation details are provided by Rockwell Automation.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-9637 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-9637

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-9637 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-9637

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Rockwell Automation Logix Platform

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-244-03.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/ICSA/white/2026/icsa-26-244-03.json

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-03

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Supplemental source

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.