PatchSiren cyber security CVE debrief
CVE-2026-9625 Rockwell Automation CVE debrief
A denial-of-service security issue exists within Rockwell Automation RSLinx Classic. A crafted CIP packet with an oversized embedded message request can cause the RSLinx Classic service to crash, requiring a restart of the service to recover. This issue affects RSLinx Classic deployments, particularly those using version 4.50 or earlier, and may lead to potential service disruption. Defenders should verify their inventory and assess potential exposure to prioritize remediation. The vulnerability has a high CVSS score of 7.5, emphasizing the need for immediate attention. The information provided in the CVE record and source item offers details on the vulnerability, but there is a a
- Vendor
- Rockwell Automation
- Product
- RSLinx Classic
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-09-01
- Original CVE updated
- 2026-09-01
- Advisory published
- 2026-09-01
- Advisory updated
- 2026-09-01
Who should care
Defenders responsible for Rockwell Automation RSLinx Classic deployments should verify their inventory, assess potential exposure, and prioritize remediation. Those using version 4.50 or earlier should take immediate action to mitigate potential impact.
Why it matters
CVE-2026-9625 is a denial-of-service vulnerability in Rockwell Automation RSLinx Classic with a high CVSS score of 7.5. Defenders should verify exposure, assess impact, and prioritize remediation, especially for version 4.50 or earlier.
- Potential service disruption due to denial-of-service vulnerability
- Need to verify exposure and assess potential impact
- Prioritize remediation for RSLinx Classic version 4.50 or earlier
- Implement security best practices to minimize potential risk
Technical summary
A crafted CIP packet with an oversized embedded message request can cause the RSLinx Classic service to crash, requiring a restart of the service to recover. The vulnerability has a CVSS score of 7.5 and affects RSLinx Classic version 4.50 or earlier. This denial-of-service vulnerability can lead to potential service disruption, emphasizing the need for defenders to verify their inventory, assess potential exposure, and prioritize remediation. Those using RSLinx Classic version 4.50 or earlier should take immediate action to mitigate potential impact. The vulnerability details are based on the CVE record and source item, which provide information on the affected product versions and CVSS score.
Defensive priority
Defenders should prioritize verifying exposure and assessing potential impact, as the vulnerability has a high CVSS score of 7.5. Those using RSLinx Classic version 4.50 or earlier should verify their inventory and assess potential exposure.
Recommended defensive actions
- Verify inventory of RSLinx Classic versions
- Assess potential exposure and impact
- Consider upgrading to RSLinx Classic version 4.60 or later
- Implement Rockwell Automation's security best practices
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented.
Evidence notes
The CVE record and source item provide details on the vulnerability, including its description, CVSS score, and affected product versions. However, there is limited information on potential exploitation or victim impact.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-9625 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-9625
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-9625 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-9625
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Rockwell Automation RSLinx Classic
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-244-01.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.