PatchSiren cyber security CVE debrief
CVE-2026-9622 Rockwell Automation CVE debrief
A denial-of-service security issue exists within Rockwell Automation RSLinx Classic. A crafted CIP packet targeting the Forward Close service can cause the RSLinx Classic service to crash, requiring a restart of the service to recover. This issue affects RSLinx Classic versions prior to 4.60 and has a CVSS score of 8.6, indicating high severity. Defenders should verify exposure and assess potential impact on industrial control systems. The vulnerability is described in the CVE record and source item, which provide details on the affected product versions and CVSS score.
- Vendor
- Rockwell Automation
- Product
- RSLinx Classic
- CVSS
- HIGH 8.6
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-09-01
- Original CVE updated
- 2026-09-01
- Advisory published
- 2026-09-01
- Advisory updated
- 2026-09-01
Who should care
Defenders responsible for industrial control systems, particularly those using Rockwell Automation RSLinx Classic, should assess exposure and potential impact. This includes verifying if RSLinx Classic versions prior to 4.60 are in use and applying vendor-provided fixes or mitigations as necessary. Security teams and vulnerability management teams should prioritize verifying exposure and assessing potential impact due to the high CVSS score of 8.6.
Why it matters
CVE-2026-9622 is a high-severity denial-of-service vulnerability in Rockwell Automation RSLinx Classic, requiring defenders to verify exposure and assess potential impact.
- Denial-of-service vulnerability requires verification of exposure and potential impact
- Restart of RSLinx Classic service may be necessary to recover from exploitation
- Industrial control systems may be affected, requiring assessment of potential consequences
Technical summary
A crafted CIP packet targeting the Forward Close service in RSLinx Classic can cause the service to crash, requiring a restart to recover. The vulnerability has a CVSS score of 8.6 and affects RSLinx Classic versions prior to 4.60. This high-severity denial-of-service vulnerability requires defenders to verify exposure and assess potential impact on industrial control systems. The CVE record and source item provide details on the affected product versions and CVSS score, offering a source-grounded technical framing of the vulnerability.
Defensive priority
Defenders should prioritize verifying exposure and assessing potential impact, as the vulnerability has a high CVSS score of 8.6.
Recommended defensive actions
- Verify exposure by checking if RSLinx Classic versions prior to 4.60 are in use
- Assess potential impact on industrial control systems
- Apply vendor-provided fix by upgrading to RSLinx Classic version 4.60 or later
- Implement security best practices for industrial control systems
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
Evidence notes
The CVE record and source item provide details on the vulnerability, including its description, CVSS score, and affected product versions. The vulnerability has a CVSS score of 8.6 and affects RSLinx Classic versions prior to 4.60. The source item provides additional information on the vulnerability and affected products. The CVE Program record and NIST NVD detail page also offer source-specific vulnerability assessments.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-9622 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-9622
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-9622 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-9622
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Rockwell Automation RSLinx Classic
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-244-01.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-244-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.