PatchSiren

PatchSiren cyber security CVE debrief

CVE-2025-10478 Rockwell Automation CVE debrief

A denial-of-service security issue exists in the Rockwell Automation 1756-ENBT module, a ControlLogix EtherNet/IP bridge. An attacker could exploit this vulnerability by sending a crafted CIP packet, causing the module to crash, requiring a restart to recover. This issue affects industrial control systems, particularly those using Rockwell Automation 1756-ENBT modules. Defenders should assess exposure and apply mitigations to prevent potential disruptions. The vulnerability has a CVSS score of 7.5 and is classified as HIGH severity.

Vendor
Rockwell Automation
Product
1756-ENBT module
CVSS
HIGH 7.5
CISA KEV
Not listed in stored evidence
Original CVE published
2026-09-03
Original CVE updated
2026-09-03
Advisory published
2026-09-03
Advisory updated
2026-09-03

Who should care

Defenders of industrial control systems, particularly those using Rockwell Automation 1756-ENBT modules, should assess exposure and apply mitigations to prevent potential disruptions. This includes operators, platform administrators, vulnerability management teams, and security teams responsible for protecting industrial control systems.

Why it matters

CVE-2025-10478 is a denial-of-service vulnerability in Rockwell Automation's 1756-ENBT module. Defenders of industrial control systems should assess exposure and apply mitigations to prevent potential disruptions.

  • Denial of service to critical industrial control systems
  • Potential disruption to industrial processes
  • Need for immediate assessment and mitigation

Technical summary

The Rockwell Automation 1756-ENBT module is vulnerable to a denial-of-service attack. An attacker could exploit this vulnerability by sending a crafted CIP packet, causing the module to crash, requiring a restart to recover. This issue affects industrial control systems, particularly those using Rockwell Automation 1756-ENBT modules. The vulnerability has a CVSS score of 7.5 and is classified as HIGH severity. The device requires a restart to recover from the attack. SSVCv2/E:N/A:N/2026-09-01T06:00:00.000000Z. The vulnerability was published on 2026-09-03T06:00:00.000Z.

Defensive priority

Immediately assess exposure and apply mitigations

Recommended defensive actions

  • Assess exposure of Rockwell Automation 1756-ENBT modules in your environment
  • Apply recommended mitigations, such as upgrading to 1756-EN2T or 1756-EN4TR
  • Implement Rockwell Automation's security best practices
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The source corpus provides details on the vulnerability and its potential impact, but does not provide information on exploitation or affected versions beyond 'all' versions. The CVE record was published on 2026-09-03T06:00:00.000Z and has not been modified since then. The Rockwell Automation 1756-ENBT module is a ControlLogix EtherNet/IP bridge that enables communication between Logix 5000 controllers and Ethernet devices.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-10478 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-10478

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-10478 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-10478

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Rockwell Automation 1756-ENBT Module

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-246-05.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-05

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Supplemental source

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.