PatchSiren cyber security CVE debrief
CVE-2024-40619 Rockwell Automation CVE debrief
A denial-of-service vulnerability exists in Rockwell Automation's ControlLogix 5580 and GuardLogix 5580 controllers. The vulnerability occurs when a malformed CIP packet is sent over the network to the device, resulting in a major nonrecoverable fault causing a denial-of-service. This issue requires immediate attention from defenders responsible for industrial control systems, particularly those using Rockwell Automation's ControlLogix 5580 and GuardLogix 5580 controllers, to assess exposure and apply updates.
- Vendor
- Rockwell Automation
- Product
- ControlLogix 5580
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-08-13
- Original CVE updated
- 2024-08-13
- Advisory published
- 2024-08-13
- Advisory updated
- 2024-08-13
Who should care
Defenders responsible for industrial control systems, particularly those using Rockwell Automation's ControlLogix 5580 and GuardLogix 5580 controllers, should assess exposure and apply updates.
Why it matters
A denial-of-service vulnerability exists in Rockwell Automation's ControlLogix 5580 and GuardLogix 5580 controllers. Defenders should prioritize verifying exposure and applying updates to affected devices.
- Denial-of-service vulnerability requires verification of exposure and application of updates
- Potential disruption to industrial control systems
- Need to monitor for suspicious network activity
Technical summary
The vulnerability occurs when a malformed CIP packet is sent over the network to the device, resulting in a major nonrecoverable fault causing a denial-of-service. Rockwell Automation has released updates to address the vulnerability. Defenders should prioritize verifying exposure and applying updates to affected devices. The vulnerability affects Rockwell Automation's ControlLogix 5580 and GuardLogix 5580 controllers, and its exploitation requires verification of exposure and application of updates to prevent potential disruption to industrial control systems.
Defensive priority
Defenders should prioritize verifying exposure and applying updates to affected devices.
Recommended defensive actions
- Verify exposure of ControlLogix 5580 and GuardLogix 5580 controllers to the network
- Apply updates to affected devices
- Implement risk mitigations
- Monitor for suspicious network activity
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
Evidence notes
The vulnerability is described in the CISA CSAF file and CVE record. Rockwell Automation has released updates to address the vulnerability. Defenders should verify the exposure of affected devices and apply updates to mitigate the vulnerability. The CISA CSAF file and CVE record provide details on the affected products and recommended actions.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-40619 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-40619
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-40619 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-40619
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Rockwell Automation GuardLogix/ControlLogix 5580 Controller
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-226-03.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-226-03
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
Supplemental source
Methodology and review provenance