PatchSiren cyber security CVE debrief
CVE-2006-0743 Rockwell Automation CVE debrief
A format string vulnerability in the log4net component of Rockwell Automation AADvance Standalone OPC-DA Server allows arbitrary code execution. The vulnerability affects versions 2.01.510 and later. Rockwell Automation has released version 2.02 to address this issue. The vulnerability is remotely exploitable with low attack complexity and requires no privileges or user interaction, though the CVSS v3.1 score of 5.3 (MEDIUM) reflects availability impact only (C:N/I:N/A:L). This CVE was published on August 13, 2024, as part of CISA's coordinated disclosure process for industrial control systems.
- Vendor
- Rockwell Automation
- Product
- Rockwell Automation AADvance Standalone OPC-DA Server: >=v2.01.510
- CVSS
- MEDIUM 5.3
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-08-13
- Original CVE updated
- 2024-08-13
- Advisory published
- 2024-08-13
- Advisory updated
- 2024-08-13
Who should care
Organizations operating Rockwell Automation AADvance Standalone OPC-DA Server in industrial control system environments, particularly those with externally accessible OPC-DA interfaces. Asset owners in critical infrastructure sectors (energy, manufacturing, water/wastewater) using this product for process data access should prioritize patching based on their SSVC analysis.
Technical summary
The vulnerability exists in the log4net logging component used by the AADvance Standalone OPC-DA Server. Format string vulnerabilities in logging frameworks can allow attackers to inject malicious format specifiers that lead to memory corruption or code execution. The affected versions (2.01.510 and later) should be updated to version 2.02 or later to remediate this vulnerability. The network-accessible nature of OPC-DA servers in industrial environments increases exposure risk, though the CVSS scoring indicates the primary impact is to availability rather than confidentiality or integrity.
Defensive priority
medium
Recommended defensive actions
- Update AADvance Standalone OPC-DA Server to version 2.02 or later per vendor guidance
- Review Rockwell Automation security best practices for industrial control systems
- Apply network segmentation and defense-in-depth strategies for OPC-DA server deployments
- Monitor for anomalous log4net-related activity in affected systems
- Use CISA's Stakeholder-Specific Vulnerability Categorization (SSVC) for environment-specific prioritization
Evidence notes
The vulnerability description and remediation guidance are derived from CISA CSAF advisory ICSA-24-226-02. The CVSS vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L indicates network attack vector, low complexity, no privileges required, no user interaction, and availability impact only. The affected product version range (>=v2.01.510) and vendor fix (v2.02 or later) are explicitly stated in the CSAF remediation section.
Sources and references
Verified primary and authoritative sources
-
CVE-2006-0743 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2006-0743
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2006-0743 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2006-0743
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-226-02.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-226-02
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.