PatchSiren cyber security CVE debrief
CVE-2024-7007 Positron S.R.L CVE debrief
CVE-2024-7007 is an authentication bypass vulnerability in the Positron Broadcast Signal Processor TRA7005, firmware version 1.20. Published by CISA on July 25, 2024, this HIGH severity issue (CVSS 3.1: 7.5) enables unauthenticated network attackers to gain unauthorized access to protected application areas. The vulnerability is network-exploitable with low attack complexity, requiring no privileges or user interaction. Notably, Positron has not responded to CISA coordination requests for mitigation, leaving users dependent on direct vendor engagement for resolution. This affects industrial broadcast infrastructure equipment, warranting immediate network segmentation and access control review.
- Vendor
- Positron S.R.L
- Product
- Broadcast Signal Processor TRA7005
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-07-25
- Original CVE updated
- 2024-07-25
- Advisory published
- 2024-07-25
- Advisory updated
- 2024-07-25
Who should care
Broadcast media organizations, telecommunications providers, and critical infrastructure operators utilizing Positron signal processing equipment; security teams responsible for industrial control system (ICS) and operational technology (OT) network protection; network administrators managing broadcast transmission infrastructure
Technical summary
The Positron Broadcast Signal Processor TRA7005 running firmware version 1.20 contains an authentication bypass vulnerability. The flaw allows unauthenticated attackers over the network to circumvent authentication controls and access protected application functionality. CVSS 3.1 scoring reflects network attack vector, low complexity, no required privileges or user interaction, with high confidentiality impact. The vulnerability is confined to confidentiality breach (no integrity or availability impact per CVSS vector). CISA's advisory indicates Positron has not engaged on coordinated vulnerability disclosure, leaving no vendor-confirmed remediation timeline.
Defensive priority
HIGH
Recommended defensive actions
- Contact Positron customer support directly for vulnerability status and patch availability, as vendor has not coordinated with CISA on mitigation
- Implement network segmentation to isolate affected TRA7005 devices from untrusted networks and internet exposure
- Restrict network access to TRA7005 management interfaces using firewall rules allowing only authorized administrative hosts
- Monitor for unauthorized access attempts to TRA7005 web/application interfaces through centralized logging
- Apply CISA ICS recommended practices for defense-in-depth strategies for industrial control systems
- Review and strengthen authentication mechanisms for any adjacent systems that may share credentials or access patterns with affected devices
Evidence notes
CISA ICS Advisory ICSA-24-207-02 confirms Positron S.R.L as vendor and TRA7005 v1.20 as affected product. CVSS 3.1 vector AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N sourced from advisory. Vendor non-response to CISA coordination explicitly stated in remediation section.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-7007 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-7007
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-7007 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-7007
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-207-02.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-207-02
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
Reference
Methodology and review provenance