PatchSiren cyber security CVE debrief
CVE-2023-46143 PHOENIX CONTACT CVE debrief
A download of code without integrity check vulnerability in Hitachi Energy RTU500 allows an unauthenticated remote attacker to modify some or all applications running on the device. Successful exploitation could result in unauthorized modification of device functionality or disruption of its intended operation. This vulnerability affects RTU500 series CMU Firmware versions 11.x and prior. Defenders should verify exposure, assess application integrity, and implement compensating controls to prevent disruptions.
- Vendor
- PHOENIX CONTACT
- Product
- RTU500 series CMU Firmware
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-09-29
- Original CVE updated
- 2026-10-06
- Advisory published
- 2026-09-29
- Advisory updated
- 2026-10-06
Who should care
Defenders responsible for industrial control systems, particularly those using Hitachi Energy RTU500 series CMU Firmware, should assess exposure and implement measures to prevent unauthorized modifications.
Why it matters
CVE-2023-46143 is a high-severity vulnerability in Hitachi Energy RTU500 that allows unauthorized modification of device functionality. Defenders should verify exposure, assess application integrity, and implement compensating controls to prevent disruptions.
- Verify exposure of RTU500 series CMU Firmware versions 11.x and prior to prevent potential disruptions
- Assess the integrity of applications running on the device to prevent unauthorized modifications
- Implement compensating controls to prevent unauthorized modifications and potential disruptions
- Prioritize upgrading to version 12.7.8 or 13.9.1 or latest to address the vulnerability
Technical summary
The vulnerability allows an unauthenticated remote attacker to modify some or all applications running on the Hitachi Energy RTU500 device, potentially disrupting its intended operation. The affected product is RTU500 series CMU Firmware versions 11.x and prior. To address this vulnerability, defenders should prioritize verifying exposure of RTU500 series CMU Firmware versions 11.x and prior, assessing the integrity of applications running on the device, and implementing compensating controls to prevent unauthorized modifications.
Defensive priority
Defenders should prioritize verifying exposure of RTU500 series CMU Firmware versions 11.x and prior, assessing the integrity of applications running on the device, and implementing compensating controls to prevent unauthorized modifications.
Recommended defensive actions
- Verify exposure of RTU500 series CMU Firmware versions 11.x and prior
- Assess the integrity of applications running on the device
- Implement compensating controls to prevent unauthorized modifications
- Upgrade to version 12.7.8 or 13.9.1 or latest
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
Evidence notes
The source corpus provides details on the vulnerability and affected products from CISA and Hitachi Energy. However, the corpus does not provide information on exploitation, victims, or specific business impacts.
Sources and references
Verified primary and authoritative sources
-
CVE-2023-46143 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2023-46143
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2023-46143 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2023-46143
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
CVE-2023-46143
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-279-06.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-279-06
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.