PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-87726 NXP CVE debrief

AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-10-08T02:04:18.602Z and has not been modified since then. CVE-2026-87726 involves insufficient API bounds checking in phalFelica within NXP's NXPNfcRdLib RC663 through version 07.14.00_Pub. This issue may allow an attacker with privileges or an untrusted third party to access unintended memory regions, potentially leading to limited loss of confidentiality, integrity, and availability. Defenders managing NFC systems using NXP's NXPNfcRdLib, especially those handling sensitive data or operating in high-integrity environments, should assess exposure and prioritize updates.

Vendor
NXP
Product
NxpNfcRdLib
CVSS
LOW 3.9
CISA KEV
Not listed in stored evidence
Original CVE published
2026-10-08
Original CVE updated
2026-10-08
Advisory published
2026-10-08
Advisory updated
2026-10-08

Who should care

Defenders managing NFC systems using NXP's NXPNfcRdLib, especially those handling sensitive data or operating in high-integrity environments, should assess exposure and prioritize updates.

Why it matters

CVE-2026-87726's insufficient API bounds checking in phalFelica within NXPNfcRdLib poses a low-severity risk, primarily affecting confidentiality, integrity, and availability. Defenders managing NFC systems, especially those handling sensitive data, should verify exposure and prioritize updates to mitigate potential risks.

  • Potential limited loss of confidentiality due to unintended memory access
  • Potential limited loss of integrity due to insufficient API bounds checking
  • Potential limited loss of availability due to memory region access issues
  • Verification of system configurations and version updates is required

Technical summary

Insufficient API bounds checking in phalFelica within NXP's NXPNfcRdLib RC663 through version 07.14.00_Pub may allow an attacker with privileges or an untrusted third party to access unintended memory regions, potentially leading to limited loss of confidentiality, integrity, and availability. The issue was confirmed by the CVE record and NXP's advisory, highlighting the need for defenders to verify exposure in NFC systems using NXP's NXPNfcRdLib, especially those with access to sensitive data or operating in high-integrity environments.

Defensive priority

Defenders should prioritize verifying exposure in NFC systems using NXP's NXPNfcRdLib, especially those with access to sensitive data or operating in high-integrity environments.

Recommended defensive actions

  • Verify NFC system configurations and versions to identify potential exposure
  • Assess the impact of insufficient API bounds checking on sensitive data access
  • Update NXPNfcRdLib to version 07.18.00 or later
  • Monitor system logs for unusual memory access patterns
  • Perform a thorough review of system configurations for any deviations from recommended settings
  • Implement compensating controls for exposed systems while remediation is scheduled and verified
  • Track and document changes to the system to ensure accountability

Evidence notes

The CVE record and NXP's advisory confirm insufficient API bounds checking in phalFelica within NXPNfcRdLib RC663 through version 07.14.00_Pub, potentially allowing access to unintended memory regions.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-87726 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-87726

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-87726 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-87726

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • CVE-2026-87726

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/87xxx/CVE-2026-87726.json

    cve_program_cvelist_v5

  • Source reference

    Unverified legacy reference

    URL: https://www.nxp.com/support/support/product-security-vulnerability:PSIRT

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://community.nxp.com/t5/Other-NXP-Products/NXPNfcRdLib-vulnerability-in-module-phalFelica-CVE-2026-87726/m-p/2414096

    Supplemental source

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.