PatchSiren cyber security CVE debrief
CVE-2025-64122 Nuvation Energy CVE debrief
CVE-2025-64122 is a high-severity Insufficiently Protected Credentials vulnerability in Nuvation Energy Multi-Stack Controller (MSC) that allows for Signature Spoofing by Key Theft. This issue affects Multi-Stack Controller (MSC): through 2.5.1. Defenders and security teams responsible for Nuvation Energy Multi-Stack Controller (MSC) deployments should assess their exposure and prioritize verification and potential upgrades. The vulnerability has a CVSS score of 7.2 and is considered HIGH severity. The CVE record was published on 2026-01-02T22:15:44.660Z and has not been modified since then.
- Vendor
- Nuvation Energy
- Product
- Multi-Stack Controller (MSC)
- CVSS
- HIGH 7.2
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-01-02
- Original CVE updated
- 2026-09-30
- Advisory published
- 2026-01-02
- Advisory updated
- 2026-09-30
Who should care
Defenders and security teams responsible for Nuvation Energy Multi-Stack Controller (MSC) deployments should assess their exposure and prioritize verification and potential upgrades.
Why it matters
CVE-2025-64122 is a high-severity vulnerability in Nuvation Energy Multi-Stack Controller (MSC) that allows for signature spoofing by key theft. Defenders should prioritize verifying and upgrading to a fixed version if currently using a version through 2.5.1, and assess their exposure to potential signature spoofing by key theft.
- Potential for signature spoofing by key theft
- Need for verification of current MSC version and potential upgrades
- Importance of secure key management practices for MSC
Technical summary
The Insufficiently Protected Credentials vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows for Signature Spoofing by Key Theft. This issue affects Multi-Stack Controller (MSC): through 2.5.1. The vulnerability has a CVSS score of 7.2 and is considered HIGH severity. Defenders should prioritize verifying and upgrading to a fixed version of Nuvation Energy Multi-Stack Controller (MSC) if currently using a version through 2.5.1, and assess their exposure to potential signature spoofing by key theft. The CVE record and NVD detail page provide more
Defensive priority
Defenders should prioritize verifying and upgrading to a fixed version of Nuvation Energy Multi-Stack Controller (MSC) if currently using a version through 2.5.1, and assess their exposure to potential signature spoofing by key theft.
Recommended defensive actions
- Verify and upgrade to a fixed version of Nuvation Energy Multi-Stack Controller (MSC) if currently using a version through 2.5.1
- Assess exposure to potential signature spoofing by key theft
- Review and implement secure key management practices for Nuvation Energy Multi-Stack Controller (MSC)
Evidence notes
The CVE record and NVD detail page provide information on the Insufficiently Protected Credentials vulnerability in Nuvation Energy Multi-Stack Controller (MSC). A third-party advisory from Dragos is also referenced.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-64122 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-64122
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-64122 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-64122
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://www.dragos.com/community/advisories/CVE-2025-64119
[email protected] - Third Party Advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.