PatchSiren cyber security CVE debrief
CVE-2023-32558 NodeJS CVE debrief
CVE-2023-32558 is a HIGH severity vulnerability (CVSS 7.5) affecting Siemens SINEC INS, published on 2024-11-12. The vulnerability stems from the use of the deprecated Node.js API `process.binding()`, which can bypass the experimental permission model through path traversal. This affects all users of Node.js 20.x with the experimental permission model enabled. At the time of CVE issuance, the permission model was explicitly noted as an experimental Node.js feature. Siemens has provided a vendor fix: update to V1.0 SP2 Update 3 or later version. The vulnerability is not listed in CISA's Known Exploited Vulnerabilities (KEV) catalog.
- Vendor
- NodeJS
- Product
- SINEC INS
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-02-13
- Original CVE updated
- 2024-03-12
- Advisory published
- 2024-02-13
- Advisory updated
- 2024-03-12
Who should care
Organizations operating Siemens SINEC INS in industrial environments, OT security teams managing Node.js-based applications, and infrastructure administrators relying on Node.js experimental permission models for access control.
Technical summary
The deprecated `process.binding()` API in Node.js 20.x enables bypass of the experimental permission model through path traversal attacks. This vulnerability affects Siemens SINEC INS deployments utilizing affected Node.js versions. The permission model, being experimental at CVE issuance time, was not intended for production security boundaries. Successful exploitation could allow unauthorized file system operations despite permission restrictions.
Defensive priority
HIGH
Recommended defensive actions
- Update Siemens SINEC INS to V1.0 SP2 Update 3 or later version as specified in vendor remediation guidance
- Review and restrict network access to SINEC INS systems to authorized hosts only
- Monitor for anomalous file system access patterns that may indicate path traversal attempts
- If Node.js 20.x experimental permission model is in use, evaluate disabling or restricting until patch is applied
- Apply defense-in-depth strategies per CISA ICS recommended practices for industrial control systems
Evidence notes
CVE description and remediation details sourced from CISA CSAF advisory ICSA-24-319-08. Vendor fix confirmed by Siemens through CSAF product tree with high confidence. CVSS vector indicates network attack vector with low attack complexity, no privileges required, and high integrity impact.
Official resources
-
CVE-2023-32558 CVE record
CVE.org
-
CVE-2023-32558 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
2024-11-12