CVE-2026-61516 is a critical information disclosure vulnerability in Netis NX10 firmware versions V4.0.1.5808 and V3.0.0.4142. An unauthenticated attacker can retrieve the administrator password by sending a request to the sysinfo action in the web management interface. This vulnerability allows attackers to establish a fully authenticated administrator session on the device.

Vendor
Netis Systems
Product
NX10
CVSS
CRITICAL 9.3
CISA KEV
Not listed in stored evidence
Original CVE published
2026-09-08
Original CVE updated
2026-09-19
Advisory published
2026-09-08
Advisory updated
2026-09-19

Who should care

Network administrators and security teams responsible for Netis NX10 devices should assess exposure and prioritize remediation to prevent unauthorized access and potential device compromise. This includes reviewing current firmware versions, restricting access to the web management interface, and monitoring for suspicious activity. IT and security teams should coordinate on applying firmware updates and verifying the effectiveness of mitigations.

Why it matters

CVE-2026-61516 is a critical information disclosure vulnerability in Netis NX10 firmware. Network administrators and security teams should assess exposure and prioritize remediation to prevent unauthorized access and potential device compromise.

  • Immediate verification of device exposure and firmware versions
  • Potential for unauthorized administrator access and device compromise
  • Need for restricted access to the web management interface
  • Priority for applying firmware updates

Technical summary

The vulnerability allows unauthenticated attackers to retrieve the administrator password by sending a request to the sysinfo action in the web management interface. This can be used to establish a fully authenticated administrator session on the device. The vulnerability affects Netis NX10 firmware versions V4.0.1.5808 and V3.0.0.4142, and immediate verification and remediation are required to prevent unauthorized access and potential device compromise. Affected systems should be identified and prioritized for patching based on criticality and exposure.

Defensive priority

High priority for immediate verification and remediation

Recommended defensive actions

  • Verify and apply firmware updates for Netis NX10 devices
  • Restrict access to the web management interface
  • Monitor for suspicious activity on the device
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and NVD entry provide details on the vulnerability. However, the exact scope of affected devices and versions requires further verification from official sources. Affected scope and potential impact should be verified with the vendor and through internal asset reviews. Official CVE and NVD documentation should be consulted for the most current information.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-61516 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-61516

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-61516 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-61516

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.