PatchSiren cyber security CVE debrief
CVE-2026-111215 Netgate CVE debrief
Netgate pfSense CE through 2.9.0 contains an OS command injection vulnerability that allows authenticated users to execute commands as root by supplying a crafted wireless parent interface name. This vulnerability can be exploited by users with limited Wireless Edit or Interface Assignments privileges, potentially leading to system compromise. System administrators and security teams should review and limit these privileges, validate and sanitize user input, and implement additional security measures to detect and prevent OS command injection attacks.
- Vendor
- Netgate
- Product
- pfSense CE
- CVSS
- HIGH 8.6
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-15
- Original CVE updated
- 2026-10-15
- Advisory published
- 2026-10-15
- Advisory updated
- 2026-10-15
Who should care
System administrators and security teams responsible for Netgate pfSense CE installations, especially those with authenticated users who have limited Wireless Edit or Interface Assignments privileges.
Why it matters
This vulnerability allows authenticated users to execute commands as root, potentially leading to system compromise. System administrators and security teams should review and limit Wireless Edit and Interface Assignments privileges, validate and sanitize user input, and implement additional security measures to detect and prevent OS command injection attacks.
- Authenticated users can execute commands as root, potentially leading to system compromise
- Limited privileges are required to exploit the vulnerability
- OS command injection attacks can be difficult to detect and prevent
Technical summary
The vulnerability is caused by the interface_wireless_clone() function interpolating unescaped input into an ifconfig shell command, allowing authenticated users to execute commands as root. This can be exploited by users with limited Wireless Edit or Interface Assignments privileges. Technical details are based on CVE Program records and supplemental sources describing the vulnerability. Defenders should review and limit privileges, validate and sanitize user input, and implement additional security measures to detect and prevent OS command injection attacks.
Defensive priority
Authenticated users with limited Wireless Edit or Interface Assignments privileges can submit malicious input to execute commands as root.
Recommended defensive actions
- Review and limit Wireless Edit and Interface Assignments privileges for authenticated users
- Validate and sanitize user input for wireless parent interface names
- Implement additional security measures to detect and prevent OS command injection attacks
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
- Plan vendor-supported updates or mitigations through normal change control where exposure is confirmed
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
Evidence notes
The vulnerability is caused by the interface_wireless_clone() function interpolating unescaped input into an ifconfig shell command. Evidence is limited to public CVE Program records and supplemental sources describing technical details. Defenders should verify affected scope, validate input sanitization, and review system logs for suspicious activity.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-111215 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-111215
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-111215 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-111215
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Netgate pfSense CE through 2.9.0 OS Command Injection via Wireless Parent Interface
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/111xxx/CVE-2026-111215.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://github.com/abraxas/pfsense-wireless-clone
Supplemental source - exploit, technical-description
-
Source reference
Unverified legacy reference
URL: https://abraxaslabs.tech/research/pfsense-ce-leftovers
Supplemental source - technical-description
-
Source reference
Unverified legacy reference
URL: https://github.com/abraxas/pfsense-assign-if-add
Supplemental source - exploit, technical-description
-
Source reference
Unverified legacy reference
URL: https://github.com/pfsense/pfsense/blob/9363ac5b8651a1c7a333180425ce7719070f95f9/src/etc/inc/interfaces.inc
Supplemental source - technical-description
-
Source reference
Unverified legacy reference
URL: https://github.com/pfsense/pfsense/blob/9363ac5b8651a1c7a333180425ce7719070f95f9/src/usr/local/www/interfaces_wireless_edit.php
Supplemental source - technical-description
-
Source reference
Unverified legacy reference
URL: https://github.com/pfsense/pfsense/blob/9363ac5b8651a1c7a333180425ce7719070f95f9/src/usr/local/www/interfaces_assign.php
Supplemental source - technical-description
-
Source reference
Unverified legacy reference
URL: https://www.vulncheck.com/advisories/netgate-pfsense-ce-through-2.9.0-os-command-injection-via-wireless-parent-interface
Supplemental source - third-party-advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.