CVE-2025-2631 National Instruments CVE debrief

CVE-2025-2631 affects National Instruments LabVIEW 2025 Q1 and earlier. According to the CISA CSAF advisory, LabVIEW can perform an out-of-bounds write when parsing user-supplied data, which may allow arbitrary code execution. The issue was publicly disclosed on 2025-04-15 and the source was revised on 2025-05-06 for typo fixes. CISA’s supplied CVSS vector is HIGH severity, and the vector indicates local access plus user interaction are required.

Vendor
National Instruments
Product
LabVIEW
CVSS
HIGH 7.8
CISA KEV
Not listed in stored evidence
Original CVE published
2025-04-15
Original CVE updated
2025-05-06
Advisory published
2025-04-15
Advisory updated
2025-05-06

Who should care

Organizations using National Instruments LabVIEW, especially teams running version 2025 Q1 or any earlier release. This is most relevant to engineering, test, automation, and industrial environments that process untrusted or externally supplied LabVIEW data.

Technical summary

The advisory describes an out-of-bounds write in LabVIEW while parsing user-supplied data. Affected products are listed as National Instruments LabVIEW: <=2025_Q1. The supplied CVSS 3.1 vector is AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, which means exploitation is rated as requiring local access and user interaction, while the potential impact is high. NI has published remediation guidance and update links in the advisory.

Defensive priority

High. Patch and verify affected LabVIEW deployments promptly, prioritizing systems that process untrusted input or are operationally sensitive.

Recommended defensive actions

  • Apply the National Instruments remediation for CVE-2025-2631 using the vendor advisory and update link provided in the source corpus.
  • Inventory LabVIEW installations and confirm whether any instance is at version 2025 Q1 or earlier.
  • Restrict who can open, import, or otherwise supply data to LabVIEW workflows until updates are applied.
  • Review operational procedures for handling externally sourced files or inputs that may be parsed by LabVIEW.
  • Track the NI advisory for any follow-up guidance or corrected release information.

Evidence notes

All statements are drawn from the supplied CISA CSAF source item and its listed references. The advisory identifies one affected product entry: National Instruments LabVIEW: <=2025_Q1. The revision history shows the 2025-05-06 update was a typo-fix revision, not a new technical disclosure. No CISA KEV entry was supplied for this CVE.