PatchSiren cyber security CVE debrief
CVE-2024-5602 National Instruments CVE debrief
A stack-based buffer overflow vulnerability in National Instruments I/O TRACE allows arbitrary code execution when a user opens a malicious .nitrace file. The vulnerability requires local access and user interaction, with a HIGH severity CVSS 3.1 score of 7.8. National Instruments has released a fix; users should apply the vendor-provided update and exercise caution with untrusted trace files.
- Vendor
- National Instruments
- Product
- I/O TRACE
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-07-23
- Original CVE updated
- 2024-07-23
- Advisory published
- 2024-07-23
- Advisory updated
- 2024-07-23
Who should care
Organizations using National Instruments I/O TRACE for hardware diagnostics and troubleshooting, particularly in industrial automation, test and measurement, and research environments. Security teams supporting engineering workstations and OT/ICS environments should prioritize this patch due to the high impact potential and common use of file sharing for diagnostic data.
Technical summary
CVE-2024-5602 is a stack-based buffer overflow in National Instruments I/O TRACE, a diagnostic tool used with NI hardware. The vulnerability is triggered when a user opens a specially crafted .nitrace file, potentially allowing an attacker to execute arbitrary code with the privileges of the running process. The CVSS 3.1 vector (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) reflects local attack vector, low attack complexity, no privileges required, user interaction required, and high impact across confidentiality, integrity, and availability. National Instruments has provided a security fix; the vendor advisory should be consulted for patch availability and installation guidance.
Defensive priority
HIGH
Recommended defensive actions
- Apply the National Instruments security update for I/O TRACE as referenced in the vendor advisory
- Train users to avoid opening .nitrace files from untrusted sources
- Implement application whitelisting to restrict execution of unauthorized software
- Follow CISA ICS recommended practices for defense-in-depth security controls
- Monitor for suspicious file handling activity in engineering workstations
Evidence notes
CISA ICS Advisory ICSA-24-205-01 confirms the stack-based buffer overflow in I/O TRACE and documents vendor remediation. CVSS vector AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H indicates local attack vector with high impact on confidentiality, integrity, and availability.
Official resources
-
CVE-2024-5602 CVE record
CVE.org
-
CVE-2024-5602 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
2024-07-23