PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-111103 mtrudel CVE debrief

The CVE-2026-111103 vulnerability is an Improper Cleanup on Thrown Exception issue in the HTTP/2 handler of mtrudel bandit. This allows an unauthenticated remote attacker to bypass per-connection resource limits via a single TCP write that carries several frames, one of which raises a stream error. The vulnerability affects bandit versions from 1.9.0 before 1.14.0. Defenders should assess exposure and prioritize verification and potential updates. The CVE record was published on 2026-10-26T13:32:06.340Z and has not been modified since then. To address this vulnerability, defenders should verify and potentially update Bandit to version 1.14.0 or later, assess exposure, and monitor

Vendor
mtrudel
Product
bandit
CVSS
HIGH 8.2
CISA KEV
Not listed in stored evidence
Original CVE published
2026-10-26
Original CVE updated
2026-11-19
Advisory published
2026-10-26
Advisory updated
2026-11-19

Who should care

Defenders responsible for systems using Bandit versions between 1.9.0 and 1.14.0 should assess exposure and prioritize verification and potential updates. This includes reviewing and updating incident response plans to address potential exploitation, verifying Bandit version, and monitoring for potential exploitation attempts.

Why it matters

This vulnerability allows an unauthenticated remote attacker to bypass per-connection resource limits in Bandit versions between 1.9.0 and 1.14.0, potentially leading to increased resource utilization.

  • Verify and potentially update Bandit to version 1.14.0 or later to prevent bypassing of per-connection resource limits
  • Assess exposure and monitor for potential exploitation attempts
  • Review and update incident response plans to address potential exploitation

Technical summary

The HTTP/2 handler of mtrudel bandit is vulnerable to an Improper Cleanup on Thrown Exception, allowing an unauthenticated remote attacker to bypass per-connection resource limits via a single TCP write that carries several frames, one of which raises a stream error. This occurs because when a frame raises StreamError partway through a chunk, Bandit.HTTP2.Handler.handle_data/3 sends RST_STREAM and continues with the connection state from before the chunk, dropping the rest of it. Streams opened by earlier frames in the chunk keep running their Plug calls, but the stream counts, last_stream_id, the rapid-reset timestamps, the HPACK decoder state and the buffer roll back, so max_concurrent_streams, max_requests,

Defensive priority

Defenders should prioritize verifying exposure and assessing the impact of this vulnerability on their systems, particularly those using Bandit versions between 1.9.0 and 1.14.0.

Recommended defensive actions

  • Verify Bandit version and assess exposure
  • Review and update Bandit to version 1.14.0 or later
  • Monitor for potential exploitation attempts
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and source item provide details on the Improper Cleanup on Thrown Exception vulnerability in the HTTP/2 handler of mtrudel bandit, which allows an unauthenticated remote attacker to bypass per-connection resource limits via a single TCP write that carries several frames, one of which raises a stream error.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-111103 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-111103

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-111103 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-111103

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • HTTP/2 StreamError recovery rolls back connection state and bypasses per-connection limits in Ba

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/111xxx/CVE-2026-111103.json

    cve_program_cvelist_v5

  • Source reference

    Unverified legacy reference

    URL: https://github.com/mtrudel/bandit/security/advisories/GHSA-2238-pgfc-w82m

    Supplemental source - vendor-advisory, related

  • Source reference

    Unverified legacy reference

    URL: https://cna.erlef.org/cves/CVE-2026-111103.html

    Supplemental source - related

  • Source reference

    Unverified legacy reference

    URL: https://osv.dev/vulnerability/EEF-CVE-2026-111103

    Supplemental source - related

  • Source reference

    Unverified legacy reference

    URL: https://github.com/mtrudel/bandit/commit/3ad49c80c268891e7cc412e69649115456638e59

    Supplemental source - related

  • Source reference

    Unverified legacy reference

    URL: https://github.com/mtrudel/bandit/commit/220b9dfd27f9a21305be2afc75cbe585ddc24e7a

    Supplemental source - patch

Methodology and review provenance