PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-133246 modified-shop CVE debrief

The CVE-2026-133246 vulnerability in modified eCommerce Shopsoftware through version 3.3.0 allows administrators to include arbitrary server files via local file inclusion in shop_content.php. This could enable execution of embedded PHP in uploaded content files or images as the web server user. Administrators and security teams should assess exposure, prioritize remediation, and verify inventory for affected versions.

Vendor
modified-shop
Product
Unknown
CVSS
HIGH 8.6
CISA KEV
Not listed in stored evidence
Original CVE published
2026-11-19
Original CVE updated
2026-11-19
Advisory published
2026-11-19
Advisory updated
2026-11-19

Who should care

Administrators and security teams responsible for modified eCommerce Shopsoftware installations should assess exposure and prioritize remediation. This includes operators managing affected deployments, platform administrators, and vulnerability management teams. They must verify inventory for affected versions, review compensating controls, and monitor for suspicious activity to prevent potential exploitation and unauthorized access.

Why it matters

CVE-2026-133246 is a high-severity local file inclusion vulnerability in modified eCommerce Shopsoftware through version 3.3.0. Administrators and security teams must assess exposure, prioritize remediation, and verify inventory for affected versions to prevent potential exploitation and unauthorized access.

  • Potential execution of arbitrary PHP code as the web server user
  • Possible unauthorized access to sensitive files and data
  • Required verification of inventory and affected versions
  • Necessity for prompt remediation to prevent exploitation

Technical summary

The modified eCommerce Shopsoftware through version 3.3.0 contains a local file inclusion vulnerability in shop_content.php. This allows administrators to include arbitrary server files by storing ../ sequences in the content manager file name, potentially executing embedded PHP in uploaded content files or images as the web server user. The vulnerability has a high severity and requires immediate attention from administrators and security teams to assess exposure and prioritize remediation. Affected product deployments should be identified, and owners assigned for follow-up.

Defensive priority

High priority for administrators and security teams to assess and remediate

Recommended defensive actions

  • Assess exposure and verify inventory for affected versions
  • Prioritize remediation for administrators and security teams
  • Monitor for suspicious activity and potential exploitation attempts
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and source item provide details on the vulnerability, affected versions, and potential impact. However, specific details on exploitation, victims, or business impact are not provided. To verify, defenders should review the official CVE Program record, assess exposure, and prioritize remediation. The vulnerability allows administrators to include arbitrary server files via local file inclusion in shop_content.php, potentially executing embedded PHP in uploaded content files or images as the web server user.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-133246 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-133246

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-133246 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-133246

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • modified eCommerce Shopsoftware through 3.3.0 Local File Inclusion via shop_content.php

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/133xxx/CVE-2026-133246.json

    cve_program_cvelist_v5

  • Source reference

    Unverified legacy reference

    URL: https://github.com/modified-shop/modified-shop/pull/3766

    Supplemental source - issue-tracking, patch

  • Source reference

    Unverified legacy reference

    URL: https://github.com/modified-shop/modified-shop/commit/1fff2b4913c77b323e56b1148d6cdd67e8e30aae

    Supplemental source - patch

  • Source reference

    Unverified legacy reference

    URL: https://github.com/vinniboy021-blip/Advisory/blob/main/modified_shopsoftware-LFI-RCE-shop_content.md

    Supplemental source - technical-description

  • Source reference

    Unverified legacy reference

    URL: https://github.com/modified-shop/modified-shop/blob/v3.3.0/shop_content.php

    Supplemental source - technical-description

  • Source reference

    Unverified legacy reference

    URL: https://github.com/modified-shop/modified-shop/blob/v3.3.0/admin/content_manager.php

    Supplemental source - technical-description

  • Source reference

    Unverified legacy reference

    URL: https://github.com/modified-shop/modified-shop

    Supplemental source - product

  • Source reference

    Unverified legacy reference

    URL: https://www.vulncheck.com/advisories/modified-ecommerce-shopsoftware-through-3.3.0-local-file-inclusion-via-shop-content-php

    Supplemental source - third-party-advisory

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.