The CTI-Transmute application contains an uncontrolled resource-consumption vulnerability in the unauthenticated /activity_timeline endpoint. This vulnerability allows a remote, unauthenticated attacker to submit an excessively large value for the user-controlled days query parameter, causing the application to retrieve and process activity data over an arbitrarily large period. This could consume excessive database, CPU, or memory resources, delay the processing of concurrent requests, or trigger an internal server error. Organizations using CTI-Transmute should be aware of this vulnerability and take steps to mitigate it by applying the patch to limit the timeline range to a minimum of one day and a maximum of 1,095 days.
- Vendor
- misp
- Product
- cti-transmute
- CVSS
- HIGH 8.7
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-08-03
- Original CVE updated
- 2026-08-26
- Advisory published
- 2026-08-03
- Advisory updated
- 2026-08-26
Who should care
Organizations using CTI-Transmute, particularly those with security teams and vulnerability management processes, should prioritize patching this vulnerability to prevent potential resource exhaustion attacks. This is especially important for operators and platforms that rely on CTI-Transmute for critical functions, as the vulnerability could lead to significant disruptions in service. Security teams should review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance, and plan vendor-supported updates or mitigations through normal change control where exposure is confirmed. Additionally, compensating controls for exposed systems should be reviewed while remediation is scheduled and verified, and relevant monitoring, detection, and logs for exposed assets should be checked for extra review. Exceptions, retested remediated assets, and closed items should be tracked only after evidence is documented. Asset inventory and source tracking are also crucial in this context to ensure comprehensive mitigation and response efforts. Monitoring and compensating controls can help mitigate the risk while patching is in progress. The vulnerability's high CVSS score of 8.7 indicates a significant risk that should be addressed promptly to protect against potential attacks. Therefore, it is essential for affected organizations to take immediate action to secure their CTI-Transmute deployments and prevent potential resource exhaustion attacks that could lead to service disruptions or other security issues. This involves not only applying patches but also implementing additional security measures such as rate limiting on the /activity_timeline endpoint and enhancing monitoring and detection capabilities for unusual activity. By taking these steps, organizations can reduce the risk associated with this vulnerability and protect their critical infrastructure from potential threats. Furthermore, it is recommended to review and update incident response plans to include procedures for handling potential resource exhaustion attacks and to ensure that security teams are prepared to respond quickly and effectively in the event of an attack. 7
Technical summary
The CTI-Transmute application contains an uncontrolled resource-consumption vulnerability in the unauthenticated /activity_timeline endpoint. The endpoint accepts a user-controlled days query parameter that was not restricted to a reasonable range. A remote, unauthenticated attacker could submit an excessively large value for this parameter, causing the application to retrieve and process activity data over an arbitrarily large period. This could consume excessive database, CPU, or memory resources, delay the processing of concurrent requests, or trigger an internal server error.
Defensive priority
Organizations using CTI-Transmute should prioritize patching this vulnerability to prevent potential resource exhaustion attacks.
Recommended defensive actions
- Apply the patch to limit the timeline range to a minimum of one day and a maximum of 1,095 days
- Monitor the /activity_timeline endpoint for unusual activity
- Implement rate limiting on the /activity_timeline endpoint
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
Evidence notes
The CVE description indicates that CTI-Transmute contains an uncontrolled resource-consumption vulnerability in the unauthenticated /activity_timeline endpoint. The endpoint accepts a user-controlled days query parameter that was not restricted to a reasonable range. A remote, unauthenticated attacker could submit an excessively large value for this parameter, causing the application to retrieve and process activity data over an arbitrarily large period.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-69079 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-69079
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-69079 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-69079
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://github.com/MISP/cti-transmute/commit/321892d26b82c8a5af1e210ee30735abb109fac2
5a6e4751-2f3f-4070-9419-94fb35b644e8
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.