PatchSiren cyber security CVE debrief
CVE-2026-61933 Microsoft CVE debrief
An out-of-bounds read in the Windows DWM Core Library allows an authorized attacker to disclose information locally. This vulnerability affects multiple versions of Windows 11 and Windows Server 2025. Microsoft has released a patch for this vulnerability. The vulnerability requires authorization and has a CVSS score of 5.5. Defenders responsible for Windows 11 and Windows Server 2025 systems should assess exposure and apply patches to prevent local information disclosure. The CVE Program record and NVD vulnerability detail provide information on this vulnerability.
- Vendor
- Microsoft
- Product
- Windows 11 Version 24H2
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-08-11
- Original CVE updated
- 2026-10-08
- Advisory published
- 2026-08-11
- Advisory updated
- 2026-10-08
Who should care
Defenders responsible for Windows 11 and Windows Server 2025 systems should assess exposure and apply patches to prevent local information disclosure.
Why it matters
CVE-2026-61933 is a medium-severity vulnerability in the Windows DWM Core Library that allows local information disclosure. Defenders responsible for Windows 11 and Windows Server 2025 systems should assess exposure and apply patches to prevent local information disclosure. The vulnerability requires authorization and has a CVSS score of 5.5.
- Local information disclosure possible for authorized attackers
- Patching required to prevent vulnerability exploitation
- Affected systems need to be updated to prevent potential disclosure
Technical summary
An out-of-bounds read in the Windows DWM Core Library allows an authorized attacker to disclose information locally. This vulnerability affects multiple versions of Windows 11 and Windows Server 2025. The vulnerability requires authorization and has a CVSS score of 5.5. Microsoft has released a patch for this vulnerability. Defenders should review and update affected Windows 11 and Windows Server 2025 systems to prevent potential disclosure.
Defensive priority
Apply patches for CVE-2026-61933 to prevent local information disclosure
Recommended defensive actions
- Apply patches for CVE-2026-61933 to prevent local information disclosure
- Review and update affected Windows 11 and Windows Server 2025 systems
- Monitor for potential local information disclosure
Evidence notes
The CVE Program record and NVD vulnerability detail provide information on this vulnerability. Microsoft has released a patch for this vulnerability. The vulnerability requires authorization and has a CVSS score of 5.5. Defenders responsible for Windows 11 and Windows Server 2025 systems should assess exposure and apply patches to prevent local information disclosure. The source item providing details on the vulnerability also confirms the patch release.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-61933 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-61933
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-61933 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-61933
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Windows DWM Core Library Information Disclosure Vulnerability
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/61xxx/CVE-2026-61933.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-61933
Supplemental source - vendor-advisory, patch
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.